Literature DB >> 14977224

Tuned vibration absorber for suppression of rest tremor in Parkinson's disease.

S M Hashemi1, M F Golnaraghi, A E Patla.   

Abstract

A simple approach for the suppression of the tremor associated with Parkinson's disease is presented. The proposed system is a tuned vibration absorber (TVA), which has been very effective in the suppression of vibrations in an experimental model of the human arm with two degrees of freedom. Theoretical and numerical methods were used to study the behaviour of the arm model and to develop an effective tremor reduction approach. Based on these studies, a vibration absorber was designed, tested numerically and fabricated for experimental testing. Experimental investigations indicated that optimum control performance was related to the position of the controller and the excitation frequency. With a distance of 160 mm from the end of forearm, the TVA was found to have the best performance, and, for different tremor frequencies, the vibration of the experimental model was reduced by more than 80%.

Entities:  

Mesh:

Year:  2004        PMID: 14977224     DOI: 10.1007/bf02351012

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  Relative contribution of individual muscles to the isometric contraction of a muscular group.

Authors:  J C Cnockaert; G Lensel; E Pertuzon
Journal:  J Biomech       Date:  1975-07       Impact factor: 2.712

2.  Motor control of voluntary arm movements. Kinematic and modelling study.

Authors:  M L Corradini; M Gentilucci; T Leo; G Rizzolatti
Journal:  Biol Cybern       Date:  1992       Impact factor: 2.086

3.  A general approach for modelling and mathematical investigation of the human upper limb.

Authors:  R Raikova
Journal:  J Biomech       Date:  1992-08       Impact factor: 2.712

4.  Attenuation of pathological tremors by functional electrical stimulation. I: Method.

Authors:  A Prochazka; J Elek; M Javidan
Journal:  Ann Biomed Eng       Date:  1992       Impact factor: 3.934

5.  A dynamic model for simulating movements of the elbow, forearm, an wrist.

Authors:  M A Lemay; P E Crago
Journal:  J Biomech       Date:  1996-10       Impact factor: 2.712

6.  Analysis of an optimal control model of multi-joint arm movements.

Authors:  N Lan
Journal:  Biol Cybern       Date:  1997-02       Impact factor: 2.086

7.  The mechanical behavior of active human skeletal muscle in small oscillations.

Authors:  S C Cannon; G I Zahalak
Journal:  J Biomech       Date:  1982       Impact factor: 2.712

8.  A mathematical model of arm swing during human locomotion.

Authors:  K M Jackson; J Joseph; S J Wyard
Journal:  J Biomech       Date:  1978       Impact factor: 2.712

9.  Evaluation of a controlled-energy-dissipation orthosis for tremor suppression.

Authors:  A S Arnold; M J Rosen; M L Aisen
Journal:  J Electromyogr Kinesiol       Date:  2006-09-19       Impact factor: 2.368

  9 in total
  8 in total

1.  Design of a noninvasive and smart hand tremor attenuation system with active control: a simulation study.

Authors:  Mahdi Abbasi; Aref Afsharfard; Roya Arasteh; Javad Safaie
Journal:  Med Biol Eng Comput       Date:  2018-01-03       Impact factor: 2.602

2.  Distribution of tremorogenic activity among the major superficial muscles of the upper limb in persons with Essential tremor.

Authors:  David J Standring; Adam C Pigg; Johanna Thompson-Westra; Karin Mente; Carine W Maurer; Dietrich Haubenberger; Mark Hallett; Steven K Charles
Journal:  Clin Neurophysiol       Date:  2022-07-16       Impact factor: 4.861

3.  Distribution of tremor among the major degrees of freedom of the upper limb in subjects with Essential Tremor.

Authors:  Adam C Pigg; Johanna Thompson-Westra; Karin Mente; Carine W Maurer; Dietrich Haubenberger; Mark Hallett; Steven K Charles
Journal:  Clin Neurophysiol       Date:  2020-09-02       Impact factor: 3.708

4.  A telemedicine instrument for remote evaluation of tremor: design and initial applications in fatigue and patients with Parkinson's disease.

Authors:  Mário C Barroso Júnior; Guilherme P Esteves; Thiago P Nunes; Lucia M G Silva; Alvaro C D Faria; Pedro L Melo
Journal:  Biomed Eng Online       Date:  2011-02-09       Impact factor: 2.819

5.  Assistive Methodologies for Parkinson's Disease Tremor Management-A Health Opinion.

Authors:  V Dineshkumar; D Raveena Judie Dolly; D J Jagannath; J Dinesh Peter
Journal:  Front Public Health       Date:  2022-04-26

6.  Tremor Reduction at the Palm of a Parkinson's Patient Using Dynamic Vibration Absorber.

Authors:  Sarah Gebai; Mohammad Hammoud; Ali Hallal; Hassan Khachfe
Journal:  Bioengineering (Basel)       Date:  2016-07-05

7.  Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression.

Authors:  Gil Herrnstadt; Carlo Menon
Journal:  Front Bioeng Biotechnol       Date:  2016-03-31

8.  Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor.

Authors:  Gil Herrnstadt; Martin J McKeown; Carlo Menon
Journal:  J Neuroeng Rehabil       Date:  2019-02-01       Impact factor: 4.262

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.