Literature DB >> 14975642

Sampling and quantifying invertebrates from drinking water distribution mains.

J Hein M van Lieverloo1, Dick W Bosboom, Geo L Bakker, Anke J Brouwer, Remko Voogt, Josje E M De Roos.   

Abstract

Water utilities in the Netherlands aim at controlling the multiplication of (micro-) organisms by distributing biologically stable water through biologically stable materials. Disinfectant residuals are absent or very low. To be able to assess invertebrate abundance, methods for sampling and quantifying these animals from distribution mains were optimised and evaluated. The presented method for collecting invertebrates consists of unidirectionally flushing a mains section with a flow rate of 1 ms(-1) and filtering the flushed water in two separate flows with 500 microm and 100 microm mesh plankton gauze filters. Removal efficiency from mains was evaluated in nine experiments by collecting the invertebrates removed from the mains section by intensive cleaning immediately subsequent to sampling. Of 12 taxa distinguished, all except case-building Chironomidae larvae (2%) and Oligochaeta (30%) were removed well (51-75%). Retention of invertebrates in 100 microm filters was evaluated by filtering 39 filtrates using 30 microm filters. Except for flexible and small invertebrates such as Turbellaria (13%), Nematoda (11%) and Copepoda larvae (24%), most taxa were well retained in the 100 microm filters (53-100%). During sample processing, the method for taking sub-samples with a 10 ml pipette from the suspension of samples with high sediment concentrations was found to perform well in 75% of the samples. During a 2-year national survey in the Netherlands and consecutive investigations, the method appeared to be very suitable to assess the abundance of most invertebrate taxa in drinking water distribution systems and to be practicable for relatively inexperienced sampling and lab technicians. Although the numbers of small, less abundant or sessile taxa were not accurately assessed using the method, these taxa probably should not be the primary focus of monitoring by water utilities, as consumer complaints are not likely to be caused by these invertebrates. The accuracy of quantifying small invertebrates was further improved, however, by filtering the 100microm filtrate with a 30microm mesh plankton gauze filter.

Entities:  

Mesh:

Year:  2004        PMID: 14975642     DOI: 10.1016/j.watres.2003.11.021

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  3 in total

1.  Unsuitability of quantitative Bacteroidales 16S rRNA gene assays for discerning fecal contamination of drinking water.

Authors:  Paul W J J van der Wielen; Gertjan Medema
Journal:  Appl Environ Microbiol       Date:  2010-05-28       Impact factor: 4.792

2.  Impact of Distribution and Network Flushing on the Drinking Water Microbiome.

Authors:  Joline El-Chakhtoura; Pascal E Saikaly; Mark C M van Loosdrecht; Johannes S Vrouwenvelder
Journal:  Front Microbiol       Date:  2018-09-19       Impact factor: 5.640

3.  Passability of Chironomid Larvae in Granular Activated Carbon.

Authors:  Cha Young Lee; Jinseok Byeon; Min Kyung Kim; Tae-Gwan Lee; Dong Gun Kim
Journal:  Int J Environ Res Public Health       Date:  2022-01-17       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.