Literature DB >> 1497532

Photogrammetric analysis of corneal trephination.

S C Pflugfelder1, T J Roussel, D Denham, W Feuer, S Mandelbaum, J M Parel.   

Abstract

We used a high-magnification shadow photogrammetric system to evaluate corneal buttons trephined from human donor globes. Whole eyes were trephined with one of five instruments: nonguarded blades held by hand or placed on a handle, Barraquer-Mateus motorized trephine, Hessberg-Barron suction trephine, or Hanna microkeratotrephine. Corneoscleral buttons were punched with one of three punches: Cottingham, Katena Lieberman guillotine, or a modified Lieberman guillotine with an increased impact force (BPEI 2). The precision (how closely buttons approximated the trephine diameter), accuracy (repeatability), acircularity (deviation from roundness), and straightness (verticality of edges) of cut were calculated from the diameter and edge profile angle measurements of buttons cut by the different instruments. These results were statistically compared. The Hanna microkeratotrephine instrument had the greatest precision and accuracy, least acircularity, and straightest edges. Of the corneal punches evaluated, the Cottingham instrument had the greatest precision; however, the BPEI 2 punch cut with the greatest accuracy and the straightest edges.

Entities:  

Mesh:

Year:  1992        PMID: 1497532     DOI: 10.1001/archopht.1992.01080200140042

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  5 in total

1.  Age-dependent Fourier model of the shape of the isolated ex vivo human crystalline lens.

Authors:  Raksha Urs; Arthur Ho; Fabrice Manns; Jean-Marie Parel
Journal:  Vision Res       Date:  2010-03-23       Impact factor: 1.886

Review 2.  [The penetrating keratoplasty. A 100-year success story].

Authors:  B Seitz; A Langenbucher; G O H Naumann
Journal:  Ophthalmologe       Date:  2005-12       Impact factor: 1.059

3.  The influence of the cutting procedure on the loss of corneal endothelial cells of the recipient eye in mechanically guided trephination.

Authors:  J Daniel; H J Huebscher
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-12       Impact factor: 3.117

4.  In vitro biometry of a human spherophakia.

Authors:  Ashik Mohamed; Mohammad J Ali; Jean-Marie A Parel; Robert C Augusteyn; Virender S Sangwan
Journal:  Clin Exp Optom       Date:  2016-08-25       Impact factor: 2.742

5.  Shape of the isolated ex-vivo human crystalline lens.

Authors:  Raksha Urs; Fabrice Manns; Arthur Ho; David Borja; Adriana Amelinckx; Jared Smith; Rakhi Jain; Robert Augusteyn; Jean-Marie Parel
Journal:  Vision Res       Date:  2008-11-08       Impact factor: 1.886

  5 in total