Literature DB >> 14972393

Diffusion characteristics of large molecules assessed by proton MRS on a whole-body MR system.

A Lehnert1, J Machann, G Helms, C D Claussen, F Schick.   

Abstract

Methods for examinations of diffusion of large molecules of the size of fatty acids or triglycerides were developed for whole body MR units. Samples of aliphatic molecules were examined to study the influence of chain length. Feasibility under in vivo conditions was tested on lard samples at 37 degrees C and on human subjects Three stimulated echo sequences with maximum b-values of 2000 s/mm(2), 20000 s/mm(2), and 80000 s/mm(2) were used to assess a wide range of mobility. Sequence timing was optimized to minimize relaxation losses of fatty tissue. Apparent diffusion coefficients (ADC) were determined from five spectra with different diffusion weighting. In-vitro experiments were performed on butanol, decanol, and oleic acid to study the influence of chain length. In vivo conditions were mimicked using lard at 37 degrees C representing a composition of substances of various chain lengths. Subcutaneous fat and tibial bone marrow were studied in three healthy volunteers. ADC of muscular lipids of the lower leg was determined in two subjects. ADC values of pure aliphatic substances were in the range between 3.2 x 10(-5) mm(2)/s for oleic acid and 37.8 x 10(-5) mm(2)/s for butanol. In vivo investigations revealed ADC values of 1.11-1.24 x 10(-5) mm(2)/s for tibial bone marrow and 1.21-2.05 x 10(-5) mm(2)/s for subcutaneous fat. Diffusion coefficients of extra- and intramyocellular lipids were 1.83-3.65 x 10(-5) mm(2)/s and 2.22-3.60 x 10(-5) mm(2)/s, respectively. The proposed technique enables determination of ADC values of relatively large molecules and of lipid tissue compartments under in vivo conditions. Diffusion properties in several human lipid compartments are reported for the first time. Incoherent voxel motion influences the in vivo results to an unknown degree because of high motion sensitivity. In vitro experiments revealed ADC values depending on the chain length of the substances, indicating a residual dependence of measured ADC's on sequence timing.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14972393     DOI: 10.1016/j.mri.2003.05.007

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  11 in total

1.  Dairy cream as a phantom material for biexponential diffusion decay.

Authors:  Z Ababneh; M Haque; S E Maier; R V Mulkern
Journal:  MAGMA       Date:  2004-11-03       Impact factor: 2.310

Review 2.  Diffusion-weighted and diffusion tensor imaging for pediatric musculoskeletal disorders.

Authors:  John D MacKenzie; Leonardo Gonzalez; Andrea Hernandez; Kai Ruppert; Diego Jaramillo
Journal:  Pediatr Radiol       Date:  2007-06-28

3.  Characteristics of diffusion-weighted stimulated echo pulse sequence in human skeletal muscle.

Authors:  Junichi Hata; Kazuo Yagi; Keigo Hikishima; Tomokazu Numano; Masami Goto; Keichi Yano
Journal:  Radiol Phys Technol       Date:  2012-08-15

Review 4.  On high b diffusion imaging in the human brain: ruminations and experimental insights.

Authors:  Robert V Mulkern; Steven J Haker; Stephan E Maier
Journal:  Magn Reson Imaging       Date:  2009-06-10       Impact factor: 2.546

5.  Robust fat suppression at 3T in high-resolution diffusion-weighted single-shot echo-planar imaging of human brain.

Authors:  Joelle E Sarlls; Carlo Pierpaoli; S Lalith Talagala; Wen-Ming Luh
Journal:  Magn Reson Med       Date:  2011-05-20       Impact factor: 4.668

6.  MRI of trabecular bone using a decay due to diffusion in the internal field contrast imaging sequence.

Authors:  Dionyssios Mintzopoulos; Jerome L Ackerman; Yi-Qiao Song
Journal:  J Magn Reson Imaging       Date:  2011-08       Impact factor: 4.813

7.  In vivo lipid diffusion coefficient measurements in rat bone marrow.

Authors:  Zaid Q Ababneh; Helene Beloeil; Charles B Berde; Anas M Ababneh; Stephan E Maier; Robert V Mulkern
Journal:  Magn Reson Imaging       Date:  2009-01-22       Impact factor: 2.546

8.  Measuring large lipid droplet sizes by probing restricted lipid diffusion effects with diffusion-weighted MRS at 3T.

Authors:  Dominik Weidlich; Julius Honecker; Oliver Gmach; Mingming Wu; Rainer Burgkart; Stefan Ruschke; Daniela Franz; Bjoern H Menze; Thomas Skurk; Hans Hauner; Ulrich Kulozik; Dimitrios C Karampinos
Journal:  Magn Reson Med       Date:  2019-01-16       Impact factor: 4.668

9.  Semiquantitative Evaluation of Muscle Repair by Diffusion Tensor Imaging in Mice.

Authors:  Junichi Hata; Sakiko Mizuno; Yawara Haga; Masayuki Shimoda; Yae Kanai; Kazuhiro Chiba; Hideyuki Okano; Masaya Nakamura; Keisuke Horiuchi
Journal:  JBMR Plus       Date:  2018-03-05

10.  Detecting Mild Lower-limb Skeletal Muscle Fatigue with Stimulated-echo q-space Imaging.

Authors:  Daisuke Nakashima; Junichi Hata; Yoshifumi Sone; Katsuya Maruyama; Thorsten Feiweier; James Hirotaka Okano; Morio Matsumoto; Masaya Nakamura; Takeo Nagura
Journal:  Magn Reson Med Sci       Date:  2020-12-18       Impact factor: 2.471

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.