Deadspace: a potential error in concentration of medication during dilutional process in neonates.

Aruchalean Watanachai1, Chittiwat Suprasongsin.   

Abstract

OBJECTIVE: To evaluate the volume of deadspace (DS) and degree of errors in concentration of medications during medication dilution with needle removable syringe (NRS) compared to needle nonremovable syringe (NNRS). MATERIAL AND
METHOD: 300 syringes were tested and divided into 3 groups as follows: The first group was 100 syringes of needle removable insulin 1 ml syringe (NRIS) with a 27 gauge needle (Terumo), the second group was 100 syringes of NRIS with a 27 gauge needle (Nipro) and third group 3 was 100 syringes of needle non removable insulin syringe (NNRIS) with a 27 gauge needle (Terumo). All syringes with needle sets (without needle cover) were weighed with a Mettler electronic balance. Volume of DS was measured and calculated using a standard method. 10 syringes of each group were randomly selected to test for degree of errors in concentration of medications during the dilutional process using standard insulin (310 micro unit per ml) as a medication for dilution. All specimens were collected by ejecting all diluents into collecting tubes and insulin concentrations were measured using radioimmunoassay technique (insulin-CT biointernational, France) twice in each sample. Concentration was then calculated back and the results were noted and analysed.
RESULTS: Means of DS in group 3 (2.4 +/- 0.8 microl) was significantly less than group 1 (49.7 +/- 00.9 microl) and group 2 (65.3 +/- 0.7 microl) (median = 2 microlitre). All three groups were significantly different from each other with the largest DS in group 2. After dilution, insulin concentrations from diluents in group 3 were still close to standard insulin (335 +/- 28 vs 310 microunits/ml), whereas group 1 and 2 were significantly higher than group 3 (1.7 and 1.9 times) and standard insulin (1.8 and 2 times).
CONCLUSIONS: DS in NRIS is not negligible and is considered a potential source of error in the concentration of medications when it is used to dilute parenteral medications in the neonatal intensive care unit (NICU).

Entities:  

Mesh:

Year:  2003        PMID: 14971520

Source DB:  PubMed          Journal:  J Med Assoc Thai        ISSN: 0125-2208


  6 in total

1.  Assessing the accuracy of intracameral phenylephrine preparation in cataract surgery.

Authors:  Stuart Guthrie; Thomas Jensen; Richard C Hartley; Kanna Ramaesh; David Lockington
Journal:  Eye (Lond)       Date:  2018-06-15       Impact factor: 3.775

2.  Strategies implementation to reduce medicine preparation error rate in neonatal intensive care units.

Authors:  Ainara Campino; Elena Santesteban; Pilar Pascual; Beatriz Sordo; Casilda Arranz; Maria Unceta; Ion Lopez-de-Heredia
Journal:  Eur J Pediatr       Date:  2015-12-15       Impact factor: 3.183

Review 3.  Accuracy of intravenous and enteral preparations involving small volumes for paediatric use: a review.

Authors:  L P Ainscough; J L Ford; C W Morecroft; M Peak; M A Turner; A J Nunn; M Roberts
Journal:  Eur J Hosp Pharm       Date:  2017-01-04

Review 4.  Interventions to reduce medication errors in neonatal care: a systematic review.

Authors:  Minh-Nha Rhylie Nguyen; Cassandra Mosel; Luke E Grzeskowiak
Journal:  Ther Adv Drug Saf       Date:  2017-12-28

5.  Development of Guidelines for Accurate Measurement of Small Volume Parenteral Products Using Syringes.

Authors:  Melanie A Jordan; Dimpa Choksi; Kelsey Lombard; Lynn R Patton
Journal:  Hosp Pharm       Date:  2019-09-06

6.  Medicine preparation errors in ten Spanish neonatal intensive care units.

Authors:  Ainara Campino; Casilda Arranz; Maria Unceta; Miguel Rueda; Beatriz Sordo; Pilar Pascual; Ion Lopez-de-Heredia; Elena Santesteban
Journal:  Eur J Pediatr       Date:  2015-08-27       Impact factor: 3.183

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.