Literature DB >> 14967722

Mechanisms of exercise intolerance: insights from tissue Doppler imaging.

Stanislaw J Skaluba1, Sheldon E Litwin.   

Abstract

BACKGROUND: A decreased ratio of early to late diastolic mitral inflow velocities (E/A <1.0) reflects slowing of left ventricular (LV) relaxation. This finding is widely believed to indicate significant diastolic dysfunction. However, E/A <1.0 is common during normal aging and often is not associated with symptoms of heart failure. We asked (1) whether slowed LV relaxation is associated with exercise intolerance and (2) whether tissue Doppler imaging of the early diastolic mitral annular velocity (Ea) is helpful in understanding mechanisms of exercise intolerance. METHODS AND
RESULTS: Patients (n=121) underwent echocardiography before maximal exercise testing. Fifty-nine subjects had E/A <1.0, and 36 subjects had E/Ea > or =10. Exercise capacity was similar in the population with a normal mitral inflow pattern and those with a slow relaxation pattern when E/Ea was <10. In contrast, the subjects with slow relaxation and E/Ea > or =10 had reduced exercise tolerance. Of all the echo and clinical parameters assessed, E/Ea had the best correlation with exercise capacity (r=-0.684, P<0.001) and was the strongest independent predictor of exercise capacity < or =7 METs by multivariate analysis (prevalence-corrected odds ratio=12.6, P<0.001). E/Ea continued to be strongly associated with exercise capacity in all age groups and in those with preserved or reduced systolic function.
CONCLUSIONS: Of the subjects with slow LV relaxation, only those with E/Ea > or =10 have objective evidence of reduced exercise tolerance. These data suggest that elevated LV filling pressures rather than slow relaxation per se reduce exercise capacity.

Entities:  

Mesh:

Year:  2004        PMID: 14967722     DOI: 10.1161/01.CIR.0000117405.74491.D2

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  43 in total

1.  Evaluation of exercise capacity using wave intensity in chronic heart failure with normal ejection fraction.

Authors:  Yoichi Takaya; Manabu Taniguchi; Motoaki Sugawara; Saori Nobusada; Kengo Kusano; Teiji Akagi; Hiroshi Ito
Journal:  Heart Vessels       Date:  2013-03       Impact factor: 2.037

2.  Noninvasive assessment of exercise tolerance using mitral annular velocities.

Authors:  Yasuyuki Hadano; Masunori Matsuzaki
Journal:  J Med Ultrason (2001)       Date:  2015-09-16       Impact factor: 1.314

Review 3.  Assessment of diastolic function: what the general cardiologist needs to know.

Authors:  Philip M Mottram; Thomas H Marwick
Journal:  Heart       Date:  2005-05       Impact factor: 5.994

Review 4.  Exercise intolerance.

Authors:  Dalane W Kitzman; Leanne Groban
Journal:  Heart Fail Clin       Date:  2008-01       Impact factor: 3.179

5.  [Exercise training in heart failure].

Authors:  F Edelmann; B Pieske
Journal:  Herz       Date:  2013-09       Impact factor: 1.443

Review 6.  New advances in quantitative echocardiography.

Authors:  Steve L Liao; Mario J Garcia
Journal:  J Nucl Cardiol       Date:  2008 Mar-Apr       Impact factor: 5.952

Review 7.  Pharmacotherapy of heart failure with normal ejection fraction (HFNEF)--a systematic review.

Authors:  Sujit Rajagopalan; Anjuman Arora; Nusrat Shafiq; Srinivas Reddy S; Promila Pandhi; Niti Mittal; Samir Malhotra
Journal:  Br J Clin Pharmacol       Date:  2011-09       Impact factor: 4.335

8.  Cardiac autonomic and left ventricular mechanics following high intensity interval training: a randomized crossover controlled study.

Authors:  Jamie M O'Driscoll; Steven M Wright; Katrina A Taylor; Damian A Coleman; Rajan Sharma; Jonathan D Wiles
Journal:  J Appl Physiol (1985)       Date:  2018-06-28

9.  Clinical impact of pre-transplant diastolic function on outcome after allogeneic hematopoietic SCT.

Authors:  N Shingai; K Kakihana; G Oshikawa; T Kobayashi; N Doki; H Sakamaki; K Ohashi
Journal:  Bone Marrow Transplant       Date:  2014-06-16       Impact factor: 5.483

10.  Impacts of mitral E/e' on myocardial contractile motion and synchronicity in heart failure patients with reduced ejection fraction: An exercise-echocardiography study.

Authors:  Yi-Chih Wang; Chih-Chieh Yu; Fu-Chun Chiu; Chia-Ti Tsai; Ling-Ping Lai; Juey-Jen Hwang; Jiunn-Lee Lin
Journal:  Clin Cardiol       Date:  2013-05-13       Impact factor: 2.882

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.