Osseointegration of a hydroxyapatite-coated multilayered mesh stem.

Hiroshi Kusakabe1, Toyonori Sakamaki, Kotaro Nihei, Yasuo Oyama, Shigeru Yanagimoto, Masaru Ichimiya, Jun Kimura, Yoshiaki Toyama.   

Abstract

A new type of porous coating for hip prostheses called "multilayered mesh" was tested under weight-bearing conditions. The surface of the stem is constructed of titanium mesh produced by etching. The hip stems of hydroxyapatite (HA)-coated multilayered mesh and conventional beads were implanted into canine right hips, and animals were killed 3, 6 and 10 weeks and 6 and 12 months after implantation. Shear strength between the implant and the bone was evaluated by the push-out test. Bone ingrowth was calculated from backscattered electron imaging-scanning electron microscopy (BEI-SEM) images of transverse sections. Toluidine blue stained sections and the BEI-SEM images were evaluated histologically. The break sites of the specimens after the push-out test were evaluated on BEI-SEM images of longitudinal sections. The mean push-out strength of the HA-coated multilayered mesh samples was greater than that of the beads-coated samples every time tested, and the HA-coated multilayered mesh implants had significantly stronger push-out strength at 3 and 6 weeks (p<0.05). The strength of the HA-coated multilayered mesh implants was even greater at 6 and 12 months, whereas the strength of the beads-coated samples decreased. The HA-coated multilayered mesh implants showed significantly higher percentages of bone ingrowth than the beads-coated implants every time tested, except at 6 months (p<0.05). At 6 and 12 months, the bone ingrowth data for the HA-coated multilayered mesh implants increased, whereas it decreased for the beads-coated implants. The new bone formation had reached the bottom of the porous area of the HA-coated multilayered mesh surface by 3 weeks, but not had reached the bottom of the conventional beads surface. At 6 and 12 months, the smaller pores of the bead surface stopped the thickening of trabecular bone, and at 12 months, the break sites were at the bone-implant interface of the bead surface, whereas they were on the bone side of the HA-coated multilayered mesh surface. The difference between the break sites was significant at 12 months (p<0.05). The HA-coated multilayered mesh stem provided faster, stronger, and more durable osseointegration than the conventional bead stem.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14967528     DOI: 10.1016/j.biomaterials.2003.09.090

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  7 in total

1.  The development of a scanning strategy for the manufacture of porous biomaterials by selective laser melting.

Authors:  R Stamp; P Fox; W O'Neill; E Jones; C Sutcliffe
Journal:  J Mater Sci Mater Med       Date:  2009-06-18       Impact factor: 3.896

2.  In vivo study of the early bone-bonding ability of Ti meshes formed with calcium titanate via chemical treatments.

Authors:  Yi Tian; Shunsuke Fujibayashi; Seiji Yamaguchi; Tomiharu Matsushita; Tadashi Kokubo; Shuichi Matsuda
Journal:  J Mater Sci Mater Med       Date:  2015-10-29       Impact factor: 3.896

Review 3.  The role of hydroxyapatite coating in joint replacement surgery - Key considerations.

Authors:  Jonathan Botterill; Harman Khatkar
Journal:  J Clin Orthop Trauma       Date:  2022-04-22

4.  Self-assembled monolayer films of phosphonates for bonding RGD to titanium.

Authors:  Andras Heijink; Jeffrey Schwartz; Mark E Zobitz; K Nicole Crowder; Gregory E Lutz; Jean D Sibonga
Journal:  Clin Orthop Relat Res       Date:  2008-01-26       Impact factor: 4.176

5.  The effect of adhesive strength of hydroxyapatite coating on the stability of hydroxyapatite-coated prostheses in vivo at the early stage of implantation.

Authors:  Yonghong Duan; Shu Zhu; Fei Guo; Jinyu Zhu; Mao Li; Jie Ma; Qingsheng Zhu
Journal:  Arch Med Sci       Date:  2012-05-09       Impact factor: 3.318

6.  Functionality-packed additively manufactured porous titanium implants.

Authors:  I A J van Hengel; F S A Gelderman; S Athanasiadis; M Minneboo; H Weinans; A C Fluit; B C J van der Eerden; L E Fratila-Apachitei; I Apachitei; A A Zadpoor
Journal:  Mater Today Bio       Date:  2020-06-03

7.  Bonit Coating Leads to Macroscopic Bone Ingrowth at 8 Weeks After Primary Total Hip Arthroplasty.

Authors:  Moritz Wagner; Alexander Brunner; Gerhard Kaufmann; Dietmar Dammerer; Paul Nardelli; Erwin Schwaighofer
Journal:  Arthroplast Today       Date:  2022-07-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.