Literature DB >> 14964681

Experimental comparison of cavity sealing ability of five dental adhesive systems after thermocycling.

Liem Cao1, Sabine Geerts, Audrey Gueders, Adelin Albert, Laurence Seidel, Joseph Charpentier.   

Abstract

PURPOSE: To evaluate the cavity sealing obtained after thermocycling with five adhesive systems in which one all-in-one adhesive was compared to three one-bottle adhesives, and to observe the effect of a low-charged resin layer added to a one-bottle adhesive.
MATERIALS AND METHODS: Twenty-five recently extracted teeth were randomly allocated to five experimental adhesive systems (n = 5 each): Optibond Solo (OS), Scotchbond 1 (SB1), PQ 1, Prompt-L-Pop (PLP), SB1+Revolution (R). On each tooth, two rectangular cavities at the cementoenamel junction were filled with a microhybrid composite (Z100) and the tested adhesives. Teeth were thermocycled and stained with AgNO3 + vitamin C. Leakage was evaluated on a 6-point (0-5) severity scale and the highest score was selected for each restoration. Results were treated by ordinal logistic regression and considered to be significant at p < 0.05.
RESULTS: No significant difference was found between leakage values for enamel and dentin interfaces. Leakage scores never exceeded 2 for OS, SB1 and SB1+R, while they reached a maximum of 5 in 20% of PLP cases. OS was significantly better than the other adhesive systems, which were statistically equivalent. The addition of a flowable composite layer on SB1 did not yield a significant difference, but tended to give better results mainly at the dentin interface.
CONCLUSION: The all-in-one adhesive PLP, because of quite variable results, seems less reliable than the one-bottle adhesives, of which OS provides significantly the best results. Addition of a flowable composite on SB1 appears to yield slightly better results.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14964681

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  4 in total

1.  Comparative Study of the Shear Bond Strength of Flowable Composite in Permanent Teeth Treated with Conventional Bur and Contact or Non-Contact Er:YAG Laser.

Authors:  Parisa Parhami; Seyed Jalal Pourhashemi; Mehdi Ghandehari; Ghasem Mighani; Nasim Chiniforush
Journal:  J Lasers Med Sci       Date:  2014

2.  Microleakage after Thermocycling of Three Self-Etch Adhesives under Resin-Modified Glass-Ionomer Cement Restorations.

Authors:  Sabine O Geerts; Laurence Seidel; Adelin I Albert; Audrey M Gueders
Journal:  Int J Dent       Date:  2010-06-06

3.  Relationship between Operator Skill and In Vitro Microleakage of Different Adhesive Systems in Class V Restorations.

Authors:  Audrey Guéders; Sabine Geerts
Journal:  ISRN Dent       Date:  2010-11-29

4.  An in vitro evaluation of leakage of two etch and rinse and two self-etch adhesives after thermocycling.

Authors:  Sabine Geerts; Amandine Bolette; Laurence Seidel; Audrey Guéders
Journal:  Int J Dent       Date:  2012-05-22