Literature DB >> 14963681

[Transcatheter closure of congenital ventricular septal defects].

P Ewert1, O Kretschmar, B Peters, H Abdul Khaliq, N Nagdyman, I Schulze-Neick, J Bass, T P Lê, P E Lange.   

Abstract

We report on the transcatheter closure of ventricular septal defects (VSD) in 26 patients with Amplatzer Occluders and Nit- Occlud Coil Systems. Twenty-one patients had a perimembranous and 5 patients a muscular VSD. Patients' age range was 5 months to 59 years (median 8 years) and their body weight 4.5 kg to 167 kg (median 28 kg). Defect diameters were 3-11 mm (median 5 mm). Sixteen patients had left ventricular volume overload and 7 patients pulmonary hypertension (median 50% of systemic pressure). Seven patients suffered from trivial or mild aortic regurgitation. Twenty-eight devices (4-12 mm; median 8 mm) were implanted (16 Amplatzer, 12 Nit-Occlud) through sheaths of 4F to 9F (median 7F). Fluoroscopy times were 8.3- 56.5 min (median 26.2 min). One coil was surgically explanted directly after intervention. One patient needed pulmonary banding due to additional VSDs. After a follow-up of 7 months (1-12 months), 2 patients had a small and 9 a minimal residual shunt. Thirteen defects were completely closed. Transcatheter closure of VSDs with new devices seems to be a promising therapy for suitable defects in different hemodynamic conditions in patients of every age.

Entities:  

Mesh:

Year:  2004        PMID: 14963681     DOI: 10.1007/s00392-004-1040-x

Source DB:  PubMed          Journal:  Z Kardiol        ISSN: 0300-5860


  6 in total

1.  Recanalisation of bilateral superior vena cava after total cavopulmonary connection. Interventional occlusion with the Amplatzer VSD Occluder.

Authors:  M Girisch; L Sieverding; R Rauch; R Kaulitz; M Gass; G Ziemer; M Hofbeck
Journal:  Z Kardiol       Date:  2005-07

2.  Assessment of shunt volumes in children with ventricular septal defects: comparative quantification of MR flow measurements and invasive oximetry.

Authors:  Anoosh Esmaeili; Rene Höhn; Arne Koch; Thomas Josef Vogl; Roland Hofstetter; Nasreddin Abolmaali
Journal:  Clin Res Cardiol       Date:  2006-07-14       Impact factor: 5.460

3.  Interventional VSD-Closure with the Nit-Occlud® Lê VSD-Coil in 110 Patients: Early and Midterm Results of the EUREVECO-Registry.

Authors:  Nikolaus A Haas; Laura Kock; Harald Bertram; Regina Boekenkamp; Daniel De Wolf; Igor Ditkivskyy; Matthias W Freund; Marc Gewillig; Christoph M Happel; Ulrike Herberg; Edvard Karthasyan; Rainer Kozlik-Feldmann; Oliver Kretschmar; Yulia Kuzmenko; Ornella Milanesi; Goetz Mueller; Giacomo Pongiglione; Stephan Schubert; Gleb Tarusinov; Christoph Kampmann
Journal:  Pediatr Cardiol       Date:  2016-11-15       Impact factor: 1.655

4.  Transhepatic approach for catheter interventions in infants and children with congenital heart disease.

Authors:  M Emmel; N Sreeram; F Pillekamp; W Boehm; K Brockmeier
Journal:  Clin Res Cardiol       Date:  2006-04-03       Impact factor: 5.460

Review 5.  Long-term Consequences of Ventricular Septal Defect Closure Using Nit-Occlud Le VSD Coil Device: A Systematic Review and Meta-Analysis.

Authors:  Mehdi Ghaderian; Farzad Shahsanaei; Samin Behdad; Safura Mozafari
Journal:  Heart Views       Date:  2022-07-23

6.  Long-term outcome of perimembranous VSD closure using the Nit-Occlud® Lê VSD coil system.

Authors:  Rainer Kozlik-Feldmann; Avraham Lorber; Horst Sievert; Peter Ewert; Christian Jux; Götz C Müller; Robert Dalla Pozza; Mustafa Yigitbasi; Dietmar Schranz; Angelika Lindinger; Omar Galal; Thomas Meinertz
Journal:  Clin Res Cardiol       Date:  2020-10-31       Impact factor: 5.460

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.