Literature DB >> 14962605

Volumetric tumor measurement using three-dimensional ultrasound: in vitro phantom study on measurement accuracy under various scanning conditions.

Seong Ho Park1, Byung Ihn Choi, Joon Koo Han, Chang Jin Yoon, Joon Woo Lee, Sam Soo Kim, Heon Han.   

Abstract

Factors influencing volumetric tumor measurement using 3-D ultrasound (US) were investigated. A 3-D US unit equipped with 4- to 8-MHz curved-array and 5- to 10-MHz linear-array mechanical volume transducers, and a US phantom made of 20 ham pieces (8.6 approximately 10.5 mL) embedded in agar gel that simulated hyperechoic tumors, were used. Volumetric tumor measurement was significantly affected by the position of US focus and tumor depth. When focus was at 2 cm and 8 cm below the transducer, 5-cm-deep tumors were measured 5.6% +/- 2.8% (mean +/- SD) and 8.3% +/- 2.2% bigger, respectively, than when focus was at 5 cm below the transducer, the same position as tumors (p < 0.01). Tumors were measured 11.8% +/- 2.9% bigger when they were 8-cm deep below the transducer than when they were 5-cm deep below the transducer (p < 0.001). Setting focus at the same position as tumors and keeping tumor depth consistent during serial 3-D US examinations may be necessary for reliable volumetric assessment of tumors.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14962605     DOI: 10.1016/j.ultrasmedbio.2003.09.010

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  A 5-MHz cylindrical dual-layer transducer array for 3-D transrectal ultrasound imaging.

Authors:  Yuling Chen; Man Nguyen; Jesse T Yen
Journal:  Ultrason Imaging       Date:  2012-07       Impact factor: 1.578

Review 2.  New paradigm for management of hepatocellular carcinoma by imaging.

Authors:  Ijin Joo; Byung Ihn Choi
Journal:  Liver Cancer       Date:  2012-09       Impact factor: 11.740

3.  Three-dimensional sonographic measurement of fetal renal volume.

Authors:  Atsushi Kuno; Eisuke Inubashiri; Kenji Kanenishi; Toshiyuki Hata
Journal:  J Med Ultrason (2001)       Date:  2006-03       Impact factor: 1.878

4.  Therapeutic response assessment using 3D ultrasound for hepatic metastasis from colorectal cancer: Application of a personalized, 3D-printed tumor model using CT images.

Authors:  Ye Ra Choi; Jung Hoon Kim; Sang Joon Park; Bo Yun Hur; Joon Koo Han
Journal:  PLoS One       Date:  2017-08-10       Impact factor: 3.240

5.  Three-dimensional imaging for hepatobiliary and pancreatic diseases: Emphasis on clinical utility.

Authors:  Soo Jin Kim; Byung Ihn Choi; Se Hyung Kim; Jae Young Lee
Journal:  Indian J Radiol Imaging       Date:  2009-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.