Literature DB >> 14961961

Pyrogen transfer across high- and low-flux hemodialysis membranes.

Viktoria Weber1, Ingrid Linsberger, Eva Rossmanith, Christoph Weber, Dieter Falkenhagen.   

Abstract

The extent to which bacterial products from contaminated dialysate enter a patient's blood depends upon the type and permeability of the hemodialysis membrane in use. This study was performed to assess the transfer of pyrogenic substances across both high- and low-flux membranes (DIAPES, Fresenius Polysulfone, Helixone, Polyamide S). All experiments were carried out in the saline-saline model. The dialysate pool was contaminated either with purified lipopolysaccharide (LPS) (250 and 500 EU/mL) or with sterile bacterial culture filtrates (20 EU/mL), and in vitro dialysis was performed under diffusive and convective conditions. A significant transfer of endotoxin was observed for both low- and high-flux DIAPES challenged with either LPS or with bacterial culture filtrates. Under identical conditions, no transfer of endotoxins was detectable across Fresenius Polysulfone and Helixone upon challenge with purified LPS. With bacterial culture filtrates, endotoxin concentrations for Polyamide S and Fresenius Polysulfone were about 10% and 1%, respectively, of those measured for DIAPES, whereas no transfer of endotoxin was detectable for Helixone. Using an alternative assay (induction of interleukin-1 receptor antagonist, IL-1Ra, in whole blood), only the DIAPES membrane showed the passage of cytokine-inducing substances. Thus, when saline is present in both the blood and dialysate compartments (i.e., the situation during predialysis priming procedures), dialysis membranes differ profoundly with respect to their permeability to endotoxins.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14961961     DOI: 10.1111/j.1525-1594.2004.47227.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  7 in total

Review 1.  The scientific principles and technological determinants of haemodialysis membranes.

Authors:  Sudhir K Bowry; Charles Chazot
Journal:  Clin Kidney J       Date:  2021-12-27

2.  Assessment of the association between increasing membrane pore size and endotoxin permeability using a novel experimental dialysis simulation set-up.

Authors:  Eva Schepers; Griet Glorieux; Sunny Eloot; Michael Hulko; Adriana Boschetti-de-Fierro; Werner Beck; Bernd Krause; Wim Van Biesen
Journal:  BMC Nephrol       Date:  2018-01-05       Impact factor: 2.388

3.  Do Bacteremic patients with end-stage renal disease have a fever when presenting to the emergency department? A paired, retrospective cohort study.

Authors:  Sarah L Weatherall; Alison B Chambers; Leonard A Mermel
Journal:  BMC Emerg Med       Date:  2020-01-09

Review 4.  Multitargeted interventions to reduce dialysis-induced systemic stress.

Authors:  Bernard Canaud; Melanie P Stephens; Milind Nikam; Michael Etter; Allan Collins
Journal:  Clin Kidney J       Date:  2021-12-27

Review 5.  Clinical relevance of abstruse transport phenomena in haemodialysis.

Authors:  Sudhir K Bowry; Fatih Kircelli; Mooppil Nandakumar; Tushar J Vachharajani
Journal:  Clin Kidney J       Date:  2021-12-27

Review 6.  Blood-incompatibility in haemodialysis: alleviating inflammation and effects of coagulation.

Authors:  Sudhir K Bowry; Fatih Kircelli; Rainer Himmele; Sagar U Nigwekar
Journal:  Clin Kidney J       Date:  2021-12-27

7.  Impact of improving quality of dialysis fluid on oxidative stress and lipid profile in hemodialysis patients.

Authors:  Driss Elkabbaj; Abdelali Bahadi; Yahia Cherrah; Mourad Errasfa; Rachid Eljaoudi
Journal:  ISRN Nephrol       Date:  2012-12-19
  7 in total