Literature DB >> 14961732

Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry.

Susan S-C Tai1, Michael J Welch.   

Abstract

Cortisol is an important diagnostic marker for the production of steroid hormones, and accurate measurements of serum cortisol are necessary for proper diagnosis of adrenal function. A candidate reference method involving isotope dilution coupled with liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(3), was added to serum, followed by equilibration and solid-phase and ethyl acetate extractions to prepare samples for liquid chromatography/mass spectrometry electrospray ionization (LC/MS-ESI) and liquid chromatography/tandem mass spectrometry electrospray ionization (LC/MS/MS-ESI) analyses. (M + H)(+) ions at m/z 363 and 366 for cortisol and its labeled internal standard were monitored for LC/MS. The transitions of (M + H)(+) --> [(M + H)(+) - 2H(2)O] at m/z 363 --> 327 and 366 --> 330 were monitored for LC/MS/MS. The accuracy of the measurement was evaluated by a comparison of results of this candidate reference method on lyophilized human serum reference materials for cortisol [Certified Reference Materials 192 and 193] with the certified values determined by gas chromatography/mass spectrometry reference methods and by a recovery study for the added cortisol. The results of this method for total cortisol agreed with the certified values within 1.1%. The recovery of the added cortisol ranged from 99.8% to 101.0%. This method was applied to the determination of cortisol in samples of frozen serum pools. Excellent precision was obtained with within-set CVs of 0.3%-1.5% and between-set CVs of 0.04%-0.4% for both LC/MS and LC/MS/MS analyses. The correlation coefficients of all linear regression lines ranged from 0.998 to 1.000. The detection limits (at a signal-to-noise ratio of approximately 3-5) were 10 and 15 pg for LC/MS and LC/MS/MS, respectively. This method, which demonstrates good accuracy and precision, and is free from interferences from structural analogues, qualifies as a candidate reference method and can be used as an alternative reference method to provide an accuracy base to which the routine methods can be compared.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14961732     DOI: 10.1021/ac034966f

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  11 in total

1.  Quantification of steroid hormones in low volume plasma and tissue homogenates of fish using LC-MS/MS.

Authors:  Mohammad-Zaman Nouri; Kevin J Kroll; Molly Webb; Nancy D Denslow
Journal:  Gen Comp Endocrinol       Date:  2020-06-27       Impact factor: 2.822

2.  Rapid and reliable steroid hormone profiling in Tursiops truncatus blubber using liquid chromatography tandem mass spectrometry (LC-MS/MS).

Authors:  Ashley S P Boggs; Tracey B Schock; Lori H Schwacke; Thomas M Galligan; Jeanine S Morey; Wayne E McFee; John R Kucklick
Journal:  Anal Bioanal Chem       Date:  2017-06-19       Impact factor: 4.142

3.  Determination of cortisol production rates with contemporary liquid chromatography-mass spectrometry to measure cortisol-d(3) dilution after infusion of deuterated tracer.

Authors:  Bethany J Klopfenstein; Jonathan Q Purnell; David D Brandon; Lorne M Isabelle; Andrea E DeBarber
Journal:  Clin Biochem       Date:  2010-12-23       Impact factor: 3.281

Review 4.  Motivations and methods for analyzing pulsatile hormone secretion.

Authors:  Johannes D Veldhuis; Daniel M Keenan; Steven M Pincus
Journal:  Endocr Rev       Date:  2008-10-21       Impact factor: 19.871

5.  Characterization of circulating steroid hormone profiles in the bottlenose dolphin (Tursiops truncatus) by liquid chromatography-tandem mass spectrometry (LC-MS/MS).

Authors:  Thomas M Galligan; Lori H Schwacke; Dorian S Houser; Randall S Wells; Teri Rowles; Ashley S P Boggs
Journal:  Gen Comp Endocrinol       Date:  2018-04-06       Impact factor: 2.822

6.  Reference materials and reference measurement procedures: an overview from a national metrology institute.

Authors:  David M Bunk
Journal:  Clin Biochem Rev       Date:  2007-11

7.  Dithiobis(succinimidyl propionate) modified gold microarray electrode based electrochemical immunosensor for ultrasensitive detection of cortisol.

Authors:  Sunil K Arya; Ganna Chornokur; Manju Venugopal; Shekhar Bhansali
Journal:  Biosens Bioelectron       Date:  2010-03-18       Impact factor: 10.618

8.  Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry.

Authors:  Susan S-C Tai; Mary Bedner; Karen W Phinney
Journal:  Anal Chem       Date:  2010-03-01       Impact factor: 6.986

9.  Development of a multi-class steroid hormone screening method using Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS).

Authors:  Ashley S P Boggs; John A Bowden; Thomas M Galligan; Louis J Guillette; John R Kucklick
Journal:  Anal Bioanal Chem       Date:  2016-04-02       Impact factor: 4.142

Review 10.  Review of the Use of Liquid Chromatography-Tandem Mass Spectrometry in Clinical Laboratories: Part I-Development.

Authors:  Brian A Rappold
Journal:  Ann Lab Med       Date:  2022-03-01       Impact factor: 3.464

View more