The detection of methamphetamine in the presence of nicotine has been successfully accomplished using in situ chemical derivatization with propyl chloroformate as the derivatization reagent and ion mobility spectrometry (IMS). The rapid detection of methamphetamine is important for forensic scientists in order to establish a chain of evidence and link criminals to the crime scene. Nicotine is pervasive in clandestine drug laboratories from cigarette smoke residue. It has been demonstrated that nicotine obscures the methamphetamine peaks in ion mobility spectrometers due to their similar charge affinities and ion mobilities, which makes their detection a challenging task. As a consequence, false positive or negative responses may arise. In situ chemical derivatization poses as a sensitive, accurate, and reproducible alternative to remove the nicotine background when detecting nanogram amounts of methamphetamine. The derivatization agent was coated onto the sample disk, and the derivatization product corresponding to propyl methamphetamine carbamate was detected. In the present study, in situ chemical derivatization was demonstrated to be a feasible method to detect methamphetamine hydrochloride as the carbamate derivative, which was baseline-resolved from the nicotine peak. Alternating least squares (ALS) was used to model the datasets. A mixture containing both compounds revealed reduced mobilities of 1.61 cm(2)/V.s and 1.54 cm(2)/V.s for methamphetamine and nicotine, respectively. The reduced mobility of propyl methamphetamine carbamate was found at 1.35 cm(2)/V.s.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14961729     DOI: 10.1021/ac035123r

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Aptamer-modified carbon nanomaterial based sorption coupled to paper spray ion mobility spectrometry for highly sensitive and selective determination of methamphetamine.

Authors:  Tahereh Zargar; Taghi Khayamian; Mohammad T Jafari
Journal:  Mikrochim Acta       Date:  2018-01-10       Impact factor: 5.833

2.  Experimental and Theoretical Investigation of Sodiated Multimers of Steroid Epimers with Ion Mobility-Mass Spectrometry.

Authors:  Christopher D Chouinard; Vinícius Wilian D Cruzeiro; Adrian E Roitberg; Richard A Yost
Journal:  J Am Soc Mass Spectrom       Date:  2016-12-02       Impact factor: 3.109

3.  The use of shift reagents in ion mobility-mass spectrometry: studies on the complexation of an active pharmaceutical ingredient with polyethylene glycol excipients.

Authors:  Mark D Howdle; Christine Eckers; Alice M-F Laures; Colin S Creaser
Journal:  J Am Soc Mass Spectrom       Date:  2008-10-09       Impact factor: 3.109

4.  Non-contact identification and differentiation of illicit drugs using fluorescent films.

Authors:  Ke Liu; Congdi Shang; Zhaolong Wang; Yanyu Qi; Rong Miao; Kaiqiang Liu; Taihong Liu; Yu Fang
Journal:  Nat Commun       Date:  2018-04-27       Impact factor: 14.919

5.  Ion mobility spectrometry for detection of skin volatiles.

Authors:  Veronika Ruzsanyi; Pawel Mochalski; Alex Schmid; Helmut Wiesenhofer; Martin Klieber; Hartmann Hinterhuber; Anton Amann
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2012-11-02       Impact factor: 3.205

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.