| Literature DB >> 14960783 |
Andre Orthen1, Hendrik Wagner, Sorin Martoiu, Heinz Amenitsch, Sigrid Bernstorff, Hans Jürgen Besch, Ralf Hendrik Menk, Kivanç Nurdan, Michael Rappolt, Albert Heinrich Walenta, Ulrich Werthenbach.
Abstract
An interpolating two-dimensional X-ray imaging detector based on a single-photon counter with gas amplification by GEM (gas electron multiplier) structures is presented. The detector system can be used for time-resolved structure research down to the micro s time domain. The prototype detector has been tested at the SAXS (small-angle X-ray scattering) beamline at ELETTRA synchrotron light source with a beam energy of 8 keV. The imaging performance is examined with apertures and standard diffraction targets. Finally, the application in a time-resolved lipid temperature-jump experiment is presented.Entities:
Mesh:
Substances:
Year: 2004 PMID: 14960783 DOI: 10.1107/S0909049503028863
Source DB: PubMed Journal: J Synchrotron Radiat ISSN: 0909-0495 Impact factor: 2.616