Stimulation artifact in surface EMG signal: effect of the stimulation waveform, detection system, and current amplitude using hybrid stimulation technique.

Francesco Mandrile1, Dario Farina, Marco Pozzo, Roberto Merletti.   

Abstract

The purpose of this study was to investigate the amplitude properties of the artifact generated on the recorded surface electromyography (EMG) signals during transcutaneous electrical muscle stimulation. The factors which were investigated are the shape of the stimulation waveform, the distance of the stimulating electrode from the recording system, the interelectrode distance of the detection system, the spatial filter used for signal detection, and the stimulation current amplitude. Surface EMG signals were recorded during electrical stimulation of the biceps brachii motor point with a linear adhesive array of eight electrodes. Electrical stimulation was applied with seven stimulation waveforms (mono- and biphasic triangular, sinusoidal, and rectangular), generated by a specifically designed neuromuscular stimulator with hybrid output stage. The stimulation peak current was linearly increased from 0 mA to the maximum tolerated by the subject. The detection systems investigated were single and double differential with interelectrode distances multiple of 5 mm. Two trials for each contraction were performed on three different days. The average rectified artifact values (both absolute and normalized with respect to the corresponding M-wave values) were computed to investigate the artifact amplitude properties. Results indicated that, while the artifact average rectified value, normalized with respect to the M-wave amplitude, depended on the distance of the detecting electrodes from the stimulation point, it did not depend on the stimulation waveform, on the current intensity, on the interelectrode distance, and on the spatial filter. It was concluded that, using hybrid stimulation techniques, the selection of particular stimulation waveforms, interelectrode distances, or spatial filters has a minor effect on the reduction of the artifact when recording M-waves.

Mesh:

Year:  2003        PMID: 14960117     DOI: 10.1109/TNSRE.2003.819791

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  9 in total

1.  Suppression of stimulus artifact contaminating electrically evoked electromyography.

Authors:  Jie Liu; Sheng Li; Xiaoyan Li; Cliff Klein; William Z Rymer; Ping Zhou
Journal:  NeuroRehabilitation       Date:  2014       Impact factor: 2.138

2.  Mechanisms of cramp contractions: peripheral or central generation?

Authors:  Marco Alessandro Minetto; Aleš Holobar; Alberto Botter; Roberta Ravenni; Dario Farina
Journal:  J Physiol       Date:  2011-10-03       Impact factor: 5.182

3.  Biomechanical loading as an alternative treatment for tremor: a review of two approaches.

Authors:  Eduardo Rocon; Juan Álvaro Gallego; Juan Manuel Belda-Lois; Julián Benito-León; José Luis Pons
Journal:  Tremor Other Hyperkinet Mov (N Y)       Date:  2012-10-10

4.  Muscle motor point identification is essential for optimizing neuromuscular electrical stimulation use.

Authors:  Massimiliano Gobbo; Nicola A Maffiuletti; Claudio Orizio; Marco A Minetto
Journal:  J Neuroeng Rehabil       Date:  2014-02-25       Impact factor: 4.262

5.  Ultrasound Echogenicity as an Indicator of Muscle Fatigue during Functional Electrical Stimulation.

Authors:  Qiang Zhang; Ashwin Iyer; Krysten Lambeth; Kang Kim; Nitin Sharma
Journal:  Sensors (Basel)       Date:  2022-01-03       Impact factor: 3.576

6.  Restoring Finger-Specific Sensory Feedback for Transradial Amputees via Non-Invasive Evoked Tactile Sensation.

Authors:  Manzhao Hao; Chih-Hong Chou; Jie Zhang; Fei Yang; Chunyan Cao; Pengyu Yin; Wenyuan Liang; Chuanxin M Niu; Ning Lan
Journal:  IEEE Open J Eng Med Biol       Date:  2020-03-19

7.  Assessment of Skeletal Muscle Contractile Properties by Radial Displacement: The Case for Tensiomyography.

Authors:  Lewis J Macgregor; Angus M Hunter; Claudio Orizio; Malcolm M Fairweather; Massimiliano Ditroilo
Journal:  Sports Med       Date:  2018-07       Impact factor: 11.136

8.  A compact system for simultaneous stimulation and recording for closed-loop myoelectric control.

Authors:  Martin A Garenfeld; Nikola Jorgovanovic; Vojin Ilic; Matija Strbac; Milica Isakovic; Jakob L Dideriksen; Strahinja Dosen
Journal:  J Neuroeng Rehabil       Date:  2021-05-25       Impact factor: 4.262

9.  A Novel Technique to Reject Artifact Components for Surface EMG Signals Recorded During Walking With Transcutaneous Spinal Cord Stimulation: A Pilot Study.

Authors:  Minjae Kim; Yaejin Moon; Jasmine Hunt; Kelly A McKenzie; Adam Horin; Matt McGuire; Keehoon Kim; Levi J Hargrove; Arun Jayaraman
Journal:  Front Hum Neurosci       Date:  2021-06-03       Impact factor: 3.169

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.