The stability of 99Tcm directly labelled to an Fab' antibody via stannous ion and mercaptoethanol reduction.

G Mardirossian1, C Wu, M Rusckowski, D J Hnatowich.   

Abstract

The anti-CEA FO23C5 F(ab')2 antibody was directly radiolabelled with 99mTcm by two methods (stannous ion and mercaptoethanol reduction) and compared in vitro and in vivo for label stability. By both methods, reduction of the F(ab')2 fragment produced primarily Fab' fragments. By both methods, the label was stable to 99Tcm-pertechnetate formation in vitro. Analysis by high performance liquid chromatography (HPLC) of serum, urine, kidney and liver homogenates from mice injected with 99Tcm-antibodies by both methods consistently showed a prominent radiolabelled peak with an estimated molecular weight of about 300 daltons. An identical peak was observed in the analysis of patient samples in a related investigation from this laboratory. Cysteine was radiolabelled with reduced 99Tcm and analysed by HPLC and thin layer chromatography (TLC); one of the 99Tcm-cysteine species so produced showed the same chromatographic behaviour as that of the 300 dalton species. In conclusion, the FO23C5 and other antibodies are stably labelled with 99Tcm via either stannous ion or mercaptoethanol reduction. In mice and in patients, the labelled proteins are either catabolized or, more likely, the 99Tcm label is transchelated such that the label is present on several low molecular weight species, the most prominent of which is postulated to be 99Tcm-cysteine.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1495677     DOI: 10.1097/00006231-199207000-00005

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  3 in total

1.  Retention of technetium-99m in infectious foci in rats after release from technetium-99m labelled human non-specific polyclonal immunoglobulin G: a dual-label study with hydrazinonicotinamido and iminothiolano immunoglobulin.

Authors:  R A Claessens; E B Koenders; W J Oyen; F H Corstens
Journal:  Eur J Nucl Med       Date:  1996-11

Review 2.  Problems of delivery of monoclonal antibodies. Pharmaceutical and pharmacokinetic solutions.

Authors:  R M Reilly; J Sandhu; T M Alvarez-Diez; S Gallinger; J Kirsh; H Stern
Journal:  Clin Pharmacokinet       Date:  1995-02       Impact factor: 6.447

3.  Technetium-99m labelled hydrazinonicotinamido human non-specific polyclonal immunoglobulin G for detection of infectious foci: a comparison with two other technetium-labelled immunoglobulin preparations.

Authors:  R A Claessens; O C Boerman; E B Koenders; W J Oyen; J W van der Meer; F H Corstens
Journal:  Eur J Nucl Med       Date:  1996-04