Continuous thermodilution cardiac output measurement in sheep.

M Yelderman1, M D Quinn, R C McKown, R C Eberhart, M L Dollar.   

Abstract

A technique has been developed to continuously measure cardiac output by means of the principles of thermodilution. Pulmonary artery catheters were modified by placing a 10 cm filament near the usual injectate port. Small amounts of heat were infused according to a randomly repeating binary on-off sequence. The distal blood temperature was recorded and cross-correlated with the heat waveform to produce a dilution curve and calculate cardiac output. The technique was compared with bolus thermodilution in seven sheep. Cardiac output ranged from 1.5 to 13.2 L/min, and heart rate varied from 59 to 180 beats/min. The linear regression between the data obtained by the two methods is represented by the equation y = 1.00x + 0.13; the correlation coefficient, R, is 0.97, and the p value is less than 0.0001.

Entities:  

Mesh:

Year:  1992        PMID: 1495292

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  8 in total

1.  Thermal safety of a filamented pulmonary artery catheter.

Authors:  M Yelderman; M D Quinn; R C McKown
Journal:  J Clin Monit       Date:  1992-04

2.  JetValve: Rapid manufacturing of biohybrid scaffolds for biomimetic heart valve replacement.

Authors:  Andrew K Capulli; Maximillian Y Emmert; Francesco S Pasqualini; Debora Kehl; Etem Caliskan; Johan U Lind; Sean P Sheehy; Sung Jin Park; Seungkuk Ahn; Benedikt Weber; Josue A Goss; Simon P Hoerstrup; Kevin Kit Parker
Journal:  Biomaterials       Date:  2017-04-18       Impact factor: 12.479

3.  Analysis of the accuracy of continuous thermodilution cardiac output measurement. Comparison with intermittent thermodilution and Fick cardiac output measurement.

Authors:  L Jacquet; G Hanique; D Glorieux; P Matte; M Goenen
Journal:  Intensive Care Med       Date:  1996-10       Impact factor: 17.440

Review 4.  Bedside assessment of myocardial performance in the critically ill.

Authors:  J N Shephard; S J Brecker; T W Evans
Journal:  Intensive Care Med       Date:  1994-08       Impact factor: 17.440

5.  Semi-continuous versus injectate cardiac output measurement in intensive care patients after cardiac surgery.

Authors:  B W Böttiger; M Soder; H Rauch; H Böhrer; J Motsch; H Bauer; E Martin
Journal:  Intensive Care Med       Date:  1996-04       Impact factor: 17.440

6.  Continuous cardiac output and left atrial pressure monitoring by long time interval analysis of the pulmonary artery pressure waveform: proof of concept in dogs.

Authors:  Da Xu; N Bari Olivier; Ramakrishna Mukkamala
Journal:  J Appl Physiol (1985)       Date:  2008-12-04

7.  Pulmonary Artery Catheter (PAC) Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM): An Ovine Cardiac Output Validation.

Authors:  Robert A Phillips; Sally G Hood; Beverley M Jacobson; Malcolm J West; Li Wan; Clive N May
Journal:  Crit Care Res Pract       Date:  2012-05-09

Review 8.  The contemporary pulmonary artery catheter. Part 2: measurements, limitations, and clinical applications.

Authors:  I T Bootsma; E C Boerma; T W L Scheeren; F de Lange
Journal:  J Clin Monit Comput       Date:  2021-03-01       Impact factor: 2.502