Literature DB >> 1494218

Prevention of catheter-related sepsis during parenteral nutrition: effect of a new connection device.

Y Inoue1, R Nezu, H Matsuda, M Fujii, S Nakai, M Wasa, Y Takagi, A Okada.   

Abstract

A prospective study was carried out to determine the clinical effect of a newly devised catheter connection method (I system) and piggyback access system. Previous studies have demonstrated that the I system avoided bacterial contamination in vitro during tubing change that Luer-Lock connectors did not. The purpose of this study was to investigate the ability of this device coupled with a new closed-system piggyback technique for multipurpose access to reduce catheter-related sepsis in clinical practice. Two hundred and thirty patients receiving total parenteral nutrition were divided into two groups. Group I (n = 106) used the I system connector and group L (n = 124) used a Luer-Lock connector. Catheters in both groups were used for multipurpose access for infusion and blood sampling. In group L, a three-way stopcock and/or pig-gyback system was used for multiple access. In group I, a newly designed closed-system piggyback was used. The incidence of catheter-related sepsis was significantly lower in group I (1.89%/catheter) than in group L (12.10%/catheter) (p < .01, chi 2 analysis), and the average duration of use of each catheter was significantly longer in group I than in Group L (p < .01 by generalized Wilcoxon test). The results of this clinical study suggest that the newly designed connection method and piggyback access system are able to reduce catheter-related sepsis.

Entities:  

Mesh:

Year:  1992        PMID: 1494218     DOI: 10.1177/0148607192016006581

Source DB:  PubMed          Journal:  JPEN J Parenter Enteral Nutr        ISSN: 0148-6071            Impact factor:   4.016


  3 in total

Review 1.  Prevention of infections caused by central venous catheters--established and novel measures.

Authors:  A Bach
Journal:  Infection       Date:  1999       Impact factor: 3.553

2.  Guidelines for the prevention of intravascular catheter-related infections.

Authors:  Naomi P O'Grady; Mary Alexander; Lillian A Burns; E Patchen Dellinger; Jeffrey Garland; Stephen O Heard; Pamela A Lipsett; Henry Masur; Leonard A Mermel; Michele L Pearson; Issam I Raad; Adrienne G Randolph; Mark E Rupp; Sanjay Saint
Journal:  Clin Infect Dis       Date:  2011-04-01       Impact factor: 9.079

3.  Needleless closed system does not reduce central venous catheter-related bloodstream infection: a retrospective study.

Authors:  Mitsuru Ishizuka; Hitoshi Nagata; Kazutoshi Takagi; Keiichi Kubota
Journal:  Int Surg       Date:  2013 Jan-Mar
  3 in total