Literature DB >> 1483507

Colloid osmotic pressure of steer crystallins: implications for the origin of the refractive index gradient and transparency of the lens.

A D Magid1, A K Kenworthy, T J McIntosh.   

Abstract

The osmotic behavior of soluble cortical and nuclear steer lens crystallins was characterized by secondary osmometry for several ionic strength and pH conditions. Osmotic pressure versus protein concentration relationships were measured for pressures up to 1.15 x 10(6) dyn cm-2. At low concentrations (< 0.2 g ml-1), the osmotic pressure increased linearly with pressure, whereas for concentrations above 0.2 g ml-1, the pressure rose more sharply, giving progressively larger changes in osmotic pressure with increasing crystallin concentration. At a given ionic strength and applied osmotic pressure, the nuclear proteins attained a higher protein concentration than did the cortical proteins. For example, at the highest osmotic pressure of 1.15 x 10(6) dyn cm-2 at pH 7.6 and 0.1 M ionic strength, the observed protein concentrations were 0.43 g ml-1 for the cortical proteins and 0.52 g ml-1 for the nuclear proteins. For both cortical and nuclear steer crystallins, the pressure rose more steeply with concentration than do pressures for calf crystallins described in the literature. The impact of these developmental differences in osmotic pressure on lens transparency is discussed. Both the nuclear and cortical crystallins exhibited ionic strength-dependent shifts in their pressure-concentration behavior. At 0.02 M ionic strength, higher pressures were observed, whereas at 0.4 M ionic strength lower pressures were observed for a given protein concentration. The crystallins were also found to equilibrate to different protein concentrations at a constant osmotic pressure and 0.1 M ionic strength over a pH range of 4-9, with a maximum concentration around pH 5 for the cortical crystallins and pH 6 for the nuclear crystallins. Thus, the adult bovine cortical and nuclear soluble lens extracts are different in their osmotic properties, reflecting underlying differences in protein composition. The results of the ionic strength and pH experiments suggest that hard-sphere, electrostatic, and Donnan forces contribute to the total colloid osmotic pressure of the lens crystallins. However, near physiologic pH and ionic strength the charges of the proteins are screened to the extent that the colloid osmotic pressure exhibits only minor changes for large changes in ionic conditions. The differences in the osmotic behavior of the cortical and nuclear proteins are consistent with a model where regional variations in the colloid osmotic properties of the proteins across the lens help support the radial refractive index gradient that is present in vertebrate lenses. The importance of a radial concentration gradient of metabolites is also discussed.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1483507     DOI: 10.1016/s0014-4835(05)80174-5

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  4 in total

1.  Static light scattering from concentrated protein solutions, I: General theory for protein mixtures and application to self-associating proteins.

Authors:  Allen P Minton
Journal:  Biophys J       Date:  2007-05-25       Impact factor: 4.033

Review 2.  The optics of the eye-lens and lenticular senescence. A review.

Authors:  B K Pierscionek; R A Weale
Journal:  Doc Ophthalmol       Date:  1995       Impact factor: 2.379

3.  Connections between connexins, calcium, and cataracts in the lens.

Authors:  Junyuan Gao; Xiurong Sun; Francisco J Martinez-Wittinghan; Xiaohua Gong; Thomas W White; Richard T Mathias
Journal:  J Gen Physiol       Date:  2004-10       Impact factor: 4.086

Review 4.  Colloid osmotic parameterization and measurement of subcellular crowding.

Authors:  T J Mitchison
Journal:  Mol Biol Cell       Date:  2019-01-15       Impact factor: 4.138

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.