Literature DB >> 1482855

Model-based interpretation of the ECG: a methodology for temporal and spatial reasoning.

D A Tong1, L E Widman.   

Abstract

A new software architecture for automatic interpretation of the electrocardiogram is presented. Using the hypothesize-and-test paradigm, a semi-quantitative physiological model and production rule-based knowledge are combined to reason about time- and space-varying characteristics of complex heart rhythms. A prototype system implementing the methodology accepts a semi-quantitative description of the onset and morphology of the P waves and QRS complexes that are observed in the body-surface electrocardiogram. A beat-by-beat explanation of the origin and consequences of each wave is produced. The output is in the standard cardiology ladder diagram format. The current prototype can perform the full differential diagnosis of 2:1 atrioventricular (AV) block, and can handle correctly complex rhythms such as AV nodal reentrant tachycardia with either hidden or visible P waves, and varying degrees of AV block.

Entities:  

Mesh:

Year:  1992        PMID: 1482855      PMCID: PMC2248041     

Source DB:  PubMed          Journal:  Proc Annu Symp Comput Appl Med Care        ISSN: 0195-4210


  6 in total

1.  Preparation of electrocardiographic data for analysis by digital electronic computer.

Authors:  H V PIPBERGER; E D FREIS; L TABACK; H L MASON
Journal:  Circulation       Date:  1960-03       Impact factor: 29.690

Review 2.  Automated electrocardiogram analysis: the state of the art.

Authors:  F Bessette; L Nguyen
Journal:  Med Inform (Lond)       Date:  1989 Jan-Mar

3.  Accuracy of commercial 24-hour electrocardiogram analyzers for quantitation of total and repetitive ventricular arrhythmias.

Authors:  D M Salerno; G Granrud; M Hodges
Journal:  Am J Cardiol       Date:  1987-12-01       Impact factor: 2.778

4.  Computer-aided electrocardiography.

Authors:  L T Sheffield
Journal:  J Am Coll Cardiol       Date:  1987-08       Impact factor: 24.094

5.  Unreliability of conventional electrocardiographic monitoring for arrhythmia detection in coronary care units.

Authors:  D W Romhilt; S S Bloomfield; T C Chou; N O Fowler
Journal:  Am J Cardiol       Date:  1973-04       Impact factor: 2.778

6.  Comparison of arrhythmia computer and conventional monitoring in coronary-care unit.

Authors:  N J Vetter; D G Julian
Journal:  Lancet       Date:  1975-05-24       Impact factor: 79.321

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.