Literature DB >> 1478202

Right ventricular conductance to establish closed-loop pacing.

M Schaldach1, E Ebner, H Hutten, G H von Knorre, W Niederlag, W Rentsch, H Volkmann, D Weber, E Wunderlich.   

Abstract

Innovations in pacing technology, which include the addition of rate-responsive features to programmable pacemakers, can improve the quality of life of patients suffering from sick sinus syndrome. Among the strategies providing rate-adaptive cardiac pacing, the most attractive is the physiological restoration of closed-loop chronotropic control. This paper describes how autonomic nervous system (ANS) control information is extracted from dynamic measures of myocardial contractile performance obtained from unipolar conductance measurements using the stimulation electrode in the right ventricular cavity. The pacemaker uses the ANS information to modulate pacing rate and restore normal physiological control of heart rate. A new algorithm, regional effective slope quantity (RQ), for isolating the ANS signal was developed. The resulting signal, ventricular inotropic parameter (VIP), is a normalized parameter proportional to the strength of the ANS inotropic signals to the myocardium. The efficacy of the ANS control concept was evaluated in multi-centre studies. Patients with AV block and VIP-controlled pulse generators performed defined exercise protocols. The ANS-controlled pacing rate and the spontaneous sinus rate were closely correlated. Blood pressure and subjective patient reports further indicated that good control of the cardiovascular circulation was achieved.

Entities:  

Mesh:

Year:  1992        PMID: 1478202     DOI: 10.1093/eurheartj/13.suppl_e.104

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  4 in total

1.  Analysis of the O-wave in acute right ventricular apex impedance measurements with a standard pacing lead in animals.

Authors:  K Järverud; S Ollmar; L A Brodin
Journal:  Med Biol Eng Comput       Date:  2002-09       Impact factor: 2.602

2.  Validating optimal function of the closed loop stimulation sensor with high right septal ventricular electrode placement in 'ablate and pace' patients.

Authors:  John Silberbauer; Paul S G Hong; Rick A Veasey; Nadeem A Maddekar; Wasing Taggu; Nikhil R Patel; Guy W Lloyd; Neil Sulke
Journal:  J Interv Card Electrophysiol       Date:  2009-07-23       Impact factor: 1.900

3.  Use of Biotronik closed loop pacemaker to treat recurrent syncope in pediatric patient with dysautonomia.

Authors:  Jennifer Shortland; Orhan Uzun; Deirdre Wilson; Graham A Stuart; Mark A Walsh
Journal:  HeartRhythm Case Rep       Date:  2016-09-15

Review 4.  Cardiac Pacing in Cardioinhibitory Reflex Syncope: Clinical Use of Closed-loop Stimulation.

Authors:  Marco Tomaino; Vincenzo Russo; Daniele Giacopelli; Alessio Gargaro; Michele Brignole
Journal:  Arrhythm Electrophysiol Rev       Date:  2021-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.