Literature DB >> 14770391

Spatial velocity profile changes along the cord in normal human fetuses: can these affect Doppler measurements of venous umbilical blood flow?

G Pennati1, M Bellotti, C De Gasperi, G Rognoni.   

Abstract

OBJECTIVE: Several studies have assumed a parabolic velocity profile through the umbilical vein (UV) to derive the mean spatial velocity that is indispensable for flow rate calculations. However, the structure and arrangement of the umbilical cord suggest that velocity profiles may vary. The aim of this study was to evaluate UV spatial flow velocity profiles at different sites along the umbilical cord.
METHODS: Ten singleton pregnancies with a gestational age between 26 and 34 weeks were included in the study. Ultrasound equipment with an inbuilt function for analysis of the spatial velocity profile along a line located in a fixed plane was used to obtain UV velocity profiles. Velocity profiles were obtained at the placental insertion and in a free intra-amniotic loop of the cord. Two-dimensional (2D) velocity distribution coefficients were evaluated as ratios between mean and maximum velocities along the investigated lines.
RESULTS: 2D velocity distribution coefficients at the placental insertion (0.85 +/- 0.03) were significantly higher (P < 0.00001) than those obtained from a free loop of cord (0.76 +/- 0.03). Values indicated that velocity profiles are approximately flat at the placental insertion and become more parabolic moving downstream. Moreover, profiles become skewed in association with cord curvature and show peculiar biphasic shapes immediately downstream from the placenta.
CONCLUSIONS: Flow velocity profiles in the UV are not perfectly parabolic and modify along the cord. These characteristics may affect the evaluation of UV blood flow rate. Copyright 2003 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2004        PMID: 14770391     DOI: 10.1002/uog.938

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  2 in total

1.  Reliability and characteristics of ultrasound measurement of fetal umbilical venous blood flow volume according to the site of measurement.

Authors:  Seiji Kanazawa; Jin Muromoto; Katsusuke Ozawa; Masashi Mikami; Kohei Ogawa; Seiji Wada; Haruhiko Sago
Journal:  J Med Ultrason (2001)       Date:  2020-01-07       Impact factor: 1.314

2.  Ultrasound parameters of early pregnancy and Doppler indices of blood vessels in the placenta and umbilical cord throughout the pregnancy period in sheep.

Authors:  Angelika Brzozowska; Tomasz Stankiewicz; Barbara Błaszczyk; Pavitra Chundekkad; Jan Udała; Natalia Wojtasiak
Journal:  BMC Vet Res       Date:  2022-08-30       Impact factor: 2.792

  2 in total