Literature DB >> 14769718

Novadaq SPY: intraoperative quality assessment in off-pump coronary artery bypass grafting.

Oliver Reuthebuch1, Achim Häussler, Michele Genoni, Reza Tavakoli, Dragan Odavic, Alexander Kadner, Marko Turina.   

Abstract

OBJECTIVES: Off-pump coronary artery bypass grafting may decrease operative morbidity when compared to on-pump bypass grafting; however, it is technically demanding and thus quality control is essential. This study assesses the clinical feasibility of a new, indocyanine green (ICG)-based imaging system (SPY; Novadaq Technologies; Toronto, ON, Canada) to monitor the quality of anastomoses and grafts in off-pump revascularization.
SETTING: Thirty-eight consecutive patients undergoing nonemergent coronary artery bypass grafting without the use of extracorporeal circulation at two Swiss cardiac surgery clinics were included. On completion of bypass grafts, the quality of the grafts was assessed using the ICG-based imaging system. The imaging device comprises an 806-nm laser light source that is used to cause ICG to fluoresce and a near infrared-sensitive charged couple device videocamera that is used to capture the fluorescence images. ICG was administered through the central venous line, and images were acquired during the first pass of the ICG through the field of view. Graft flow (qualitative) and the quality of the grafts and anastomoses were assessed intraoperatively.
RESULTS: Between March 2002 and September 2002, a total of 38 patients (26 men and 12 women; mean +/- SD age, 64.6 +/- 10.5 years; body mass index, 27.1 +/- 2.9) underwent surgery and imaging at two institutions. One hundred seven of 124 grafts (45 arteries and 62 veins) were analyzed. Seventeen grafts could not be assessed due to difficulties in positioning. The imaging system was easy to handle, and no adverse reactions to ICG were observed. Four of the 107 grafts imaged required revision (three anastomotic constrictions and one graft dissection). Each imaging sequence required approximately 1.25 to 2.5 mg of ICG. The images were equivalent to angiography without the need for radiographs and catheter insertion. In addition, the course of coronaries that would otherwise be difficult to locate in obese patients could be detected using the imaging system. Biochemical and ECG data demonstrated an absence of intraoperative or postoperative myocardial damage, and no liver enzyme elevation or renal dysfunction.
CONCLUSIONS: This study supports the clinical utility of a ICG-based imaging system for the assessment of the quality of bypass grafts, which appears to be safe and simple to use.

Entities:  

Mesh:

Year:  2004        PMID: 14769718     DOI: 10.1378/chest.125.2.418

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  48 in total

1.  Use of panitumumab-IRDye800 to image microscopic head and neck cancer in an orthotopic surgical model.

Authors:  C Hope Heath; Nicholas L Deep; Larissa Sweeny; Kurt R Zinn; Eben L Rosenthal
Journal:  Ann Surg Oncol       Date:  2012-06-06       Impact factor: 5.344

Review 2.  Image-guided surgery using invisible near-infrared light: fundamentals of clinical translation.

Authors:  Sylvain Gioux; Hak Soo Choi; John V Frangioni
Journal:  Mol Imaging       Date:  2010-10       Impact factor: 4.488

Review 3.  The clinical use of indocyanine green as a near-infrared fluorescent contrast agent for image-guided oncologic surgery.

Authors:  Boudewijn E Schaafsma; J Sven D Mieog; Merlijn Hutteman; Joost R van der Vorst; Peter J K Kuppen; Clemens W G M Löwik; John V Frangioni; Cornelis J H van de Velde; Alexander L Vahrmeijer
Journal:  J Surg Oncol       Date:  2011-04-14       Impact factor: 3.454

4.  Quantitative assessment technique of HyperEye medical system angiography for coronary artery bypass grafting.

Authors:  Masaki Yamamoto; Hideaki Nishimori; Takemi Handa; Takashi Fukutomi; Kazuki Kihara; Miwa Tashiro; Takayuki Sato; Kazumasa Orihashi
Journal:  Surg Today       Date:  2016-06-28       Impact factor: 2.549

5.  Localization and quantification of platelet-rich thrombi in large blood vessels with near-infrared fluorescence imaging.

Authors:  Robert Flaumenhaft; Eiichi Tanaka; Gwenda J Graham; Alec M De Grand; Rita G Laurence; Kozo Hoshino; Roger J Hajjar; John V Frangioni
Journal:  Circulation       Date:  2006-12-18       Impact factor: 29.690

6.  Qualitative angiographic and quantitative myocardial perfusion assessment using fluorescent cardiac imaging during graded coronary artery bypass stenosis.

Authors:  Christian Detter; Detlef Russ; Jan Felix Kersten; Hermann Reichenspurner; Sabine Wipper
Journal:  Int J Cardiovasc Imaging       Date:  2017-07-15       Impact factor: 2.357

7.  Antiangiogenic antibody improves melanoma detection by fluorescently labeled therapeutic antibodies.

Authors:  Larissa Sweeny; Andrew Prince; Neel Patel; Lindsay S Moore; Eben L Rosenthal; Brian B Hughley; Jason M Warram
Journal:  Laryngoscope       Date:  2016-08-31       Impact factor: 3.325

8.  Evaluation of lymph flow patterns in splenic flexural colon cancers using laparoscopic real-time indocyanine green fluorescence imaging.

Authors:  Jun Watanabe; Mitsuyoshi Ota; Yusuke Suwa; Atsushi Ishibe; Hidenobu Masui; Kaoru Nagahori
Journal:  Int J Colorectal Dis       Date:  2016-10-01       Impact factor: 2.571

9.  Fluorescently labeled therapeutic antibodies for detection of microscopic melanoma.

Authors:  Kristine E Day; Lauren N Beck; Nicholas L Deep; Joy Kovar; Kurt R Zinn; Eben L Rosenthal
Journal:  Laryngoscope       Date:  2013-04-24       Impact factor: 3.325

10.  Use of panitumumab-IRDye800 to image cutaneous head and neck cancer in mice.

Authors:  C Hope Heath; Nicholas L Deep; Lauren N Beck; Kristine E Day; Larissa Sweeny; Kurt R Zinn; Conway C Huang; Eben L Rosenthal
Journal:  Otolaryngol Head Neck Surg       Date:  2013-03-22       Impact factor: 3.497

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.