Literature DB >> 14768730

Magnetization transfer, HASTE, and FLAIR imaging.

Zoran Rumboldt1, Miljenko Marotti.   

Abstract

Continuous technologic developments and research have increased the clinical applications of MT, HASTE, and FLAIR imaging in neuroradiology. HASTE has become the MR imaging sequence of choice for fetal neuroimaging. Other promising uses, such as for diffusion-weighted imaging, have not been fully exploited. FLAIR has been firmly established as one of the cornerstones of brain imaging; however, post-contrast FLAIR images have not offered a clear advantage over standard T1-weighted images as suggested by early studies. FLAIR imaging with echoplanar acquisition is not considered advantageous, because the decreased imaging times are obtained at the expense of lower sensitivity. For a number of applications, diffusion-weighted imaging has surpassed FLAIR. Nevertheless, FLAIR images may be more sensitive for the detection of acute brain infarction. Recently described methods for the elimination of CSF flow artifacts may lead to improved quality and reliability of FLAIR images for subarachnoid space disease. MT preparation is now routinely incorporated in time-of-flight MR angiography and gradient-echo T2*-weighted spine imaging sequences and provides increased sensitivity for postcontrast MR imaging. These applications may not be advantageous in all clinical settings. MTR analysis offers valuable information for an increasing number of pathologic processes but has not yet gained wide clinical acceptance owing to sophisticated postprocessing and significant intercenter variations. Different modifications of these techniques are being evaluated, and further developments are expected.

Entities:  

Mesh:

Year:  2003        PMID: 14768730     DOI: 10.1016/s1064-9689(03)00058-8

Source DB:  PubMed          Journal:  Magn Reson Imaging Clin N Am        ISSN: 1064-9689            Impact factor:   2.266


  5 in total

1.  MRI investigation of normal fetal lung maturation using signal intensities on different imaging sequences.

Authors:  Csilla Balassy; Gregor Kasprian; Peter C Brugger; Michael Weber; Bence Csapo; Christoph Mittermayer; Marcus Hörmann; Daniela Prayer
Journal:  Eur Radiol       Date:  2006-10-03       Impact factor: 5.315

2.  Targeted PARACEST nanoparticle contrast agent for the detection of fibrin.

Authors:  Patrick M Winter; Kejia Cai; Junjie Chen; Christopher R Adair; Garry E Kiefer; Phillip S Athey; Patrick J Gaffney; Carolyn E Buff; J David Robertson; Shelton D Caruthers; Samuel A Wickline; Gregory M Lanza
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

3.  Multi-parametric neuroimaging reproducibility: a 3-T resource study.

Authors:  Bennett A Landman; Alan J Huang; Aliya Gifford; Deepti S Vikram; Issel Anne L Lim; Jonathan A D Farrell; John A Bogovic; Jun Hua; Min Chen; Samson Jarso; Seth A Smith; Suresh Joel; Susumu Mori; James J Pekar; Peter B Barker; Jerry L Prince; Peter C M van Zijl
Journal:  Neuroimage       Date:  2010-11-20       Impact factor: 6.556

4.  Diffusion-weighted imaging, apparent diffusion coefficients, and fluid-attenuated inversion recovery MR imaging in endophthalmitis.

Authors:  Zoran Rumboldt; Christopher Moses; Ursula Wieczerzynski; Ranjiv Saini
Journal:  AJNR Am J Neuroradiol       Date:  2005-08       Impact factor: 3.825

5.  A Histopathological Scheme for the Quantitative Scoring of Intervertebral Disc Degeneration and the Therapeutic Utility of Adult Mesenchymal Stem Cells for Intervertebral Disc Regeneration.

Authors:  Cindy C Shu; Margaret M Smith; Susan M Smith; Andrew J Dart; Christopher B Little; James Melrose
Journal:  Int J Mol Sci       Date:  2017-05-12       Impact factor: 5.923

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.