Literature DB >> 14763804

Simultaneous analysis of amino acid and biogenic polyamines by high-performance liquid chromatography after pre-column derivatization with N-(9-fluorenylmethoxycarbonyloxy)succinimide.

Valentin Lozanov1, Stefan Petrov, Vanio Mitev.   

Abstract

A high-performance liquid chromatography method for the simultaneous analysis of amino acids and biogenic polyamines, using a new procedure for pre-column derivatization of amino groups with N-(9-fluorenylmethoxycarbonyloxy)succinimide is described. The separation of 20 amino acids and 4 biogenic polyamines was achieved within 32 min on a sequence of three short (50 mm) reversed-phase C18, 5 microm columns by elution buffers based on dibutylamine phosphate. The method linearity, calculated for each amino acid and polyamine, has a correlation coefficient higher than 0.991, in concentrations ranging from 0.2 to 50 microM, except for spermine and methionine, where the correlation coefficients were r = 0.984 and r = 0.979, respectively. The stability of derivatives in acidified samples at 4 degrees C and room temperature was demonstrated. The limit of quantitation was estimated to be around 50 pM in 50 microl sample injection. The repeatability of the method, expressed as R.S.D., ranged from 1.1 to 6.7%. The presented method was applied for the quantitation of amino acid and polyamine contents in beer, wine, and cell culture samples, using 2-aminoheptanoic acid or 1,7-diaminoheptane as internal standard.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14763804     DOI: 10.1016/j.chroma.2003.10.094

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Quantification of biogenic amines by microchip electrophoresis with chemiluminescence detection.

Authors:  Shulin Zhao; Yong Huang; Ming Shi; Yi-Ming Liu
Journal:  J Chromatogr A       Date:  2009-05-03       Impact factor: 4.759

2.  One single amino Acid for estimation the content of total free amino acids in qingkailing injection using high-performance liquid chromatography-diode array detection.

Authors:  Li Zhang; Xue Wang; Jiankun Su; Haiyu Liu; Zhixin Zhang; Lingling Qin; Cheng He; Long Peng; Mingxing Guo; Xiaoyan Gao
Journal:  J Anal Methods Chem       Date:  2014-03-13       Impact factor: 2.193

3.  The Effect of Different Porogens on Porous PMMA Microspheres by Seed Swelling Polymerization and Its Application in High-Performance Liquid Chromatography.

Authors:  Bing Yu; Tingting Xue; Long Pang; Xiulan Zhang; Youqing Shen; Hailin Cong
Journal:  Materials (Basel)       Date:  2018-04-29       Impact factor: 3.623

4.  Liquid Chromatographic Determination of Biogenic Amines in Fish Based on Pyrene Sulfonyl Chloride Pre-Column Derivatization.

Authors:  Elvira S Plakidi; Niki C Maragou; Marilena E Dasenaki; Nikolaos C Megoulas; Michael A Koupparis; Nikolaos S Thomaidis
Journal:  Foods       Date:  2020-05-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.