Literature DB >> 14760981

Reliability of bench tests of interface pressure.

Stephen Sprigle1, William Dunlop, Larry Press.   

Abstract

Determination of an appropriate wheelchair cushion to optimize loading on buttock tissue is crucial to pressure ulcer prevention. Standardized test methods aim to simplify selection by helping clinicians and users identify a class or category of cushions that will meet the important medical need of adequate pressure distribution. The objective of this project was to determine the test-retest reliability of interface pressure measurements taken using bench tests as opposed to human subject tests. Ten wheelchair cushions were tested following the methods for interface pressure measurement as defined in a draft International Organization for Standardization document. Dispersion index, contact area, percent force in the ischial regions, peak pressure index, and seating pressure index-standard deviation are reliable measures. Average pressure is reliable but not very volatile between cushions. The data also indicate that peak pressure, seating pressure index-skew (SPI-sk), and the other five percent force regions are not reliable. Certain bench interface pressure variables were found to have adequate intralaboratory repeatability. Interlaboratory reliability must also be tested. If a bench interface pressure test is used to indicate cushion performance, its validity should also be studied. Research is underway to relate interface pressure variables to clinical measurements of wheelchair users. Once validity is shown, standardized test results can then be used by clinicians to simplify and improve the wheelchair cushion selection process.

Entities:  

Mesh:

Year:  2003        PMID: 14760981     DOI: 10.1080/10400435.2003.10131889

Source DB:  PubMed          Journal:  Assist Technol        ISSN: 1040-0435


  7 in total

1.  Influence of wheelchair footrest height on ischial tuberosity pressure in individuals with paraplegia.

Authors:  P Tederko; T Besowski; K Jakubiak; M Łyp; K Bobecka-Wesołowska; J Kiwerski
Journal:  Spinal Cord       Date:  2015-01-20       Impact factor: 2.772

2.  Influence of wheelchair user interface and personal characteristics on static and dynamic pretibial skin pressures in elite wheelchair racers, a pilot study.

Authors:  Ian Rice; Joseph Peters; Laura Rice; Yih-Kuen Jan
Journal:  J Spinal Cord Med       Date:  2018-08-21       Impact factor: 1.985

3.  Dynamic changes in seating pressure gradient in wheelchair users with spinal cord injury.

Authors:  Chi-Wen Lung; Tim D Yang; Ben-Yi Liau; Waifong Catherine Cheung; Sanjiv Jain; Yih-Kuen Jan
Journal:  Assist Technol       Date:  2019-01-15

4.  Nonnegative matrix factorization for the identification of pressure ulcer risks from seating interface pressures in people with spinal cord injury.

Authors:  Tim D Yang; Yih-Kuen Jan
Journal:  Med Biol Eng Comput       Date:  2019-12-12       Impact factor: 2.602

5.  Procedure to categorize wheelchair cushion performance using compliant buttock models.

Authors:  Stephen Sprigle; Yogesh Deshpande
Journal:  Front Bioeng Biotechnol       Date:  2022-09-30

6.  The effect of a trunk release maneuver on Peak Pressure Index, trunk displacement and perceived discomfort in older adults seated in a High Fowler's position: a randomized controlled trial.

Authors:  Krista L Best; Guylaine Desharnais; Jeanette Boily; William C Miller; Pat G Camp
Journal:  BMC Geriatr       Date:  2012-11-16       Impact factor: 3.921

7.  Investigation of peak pressure index parameters for people with spinal cord injury using wheelchair tilt-in-space and recline: methodology and preliminary report.

Authors:  Chi-Wen Lung; Tim D Yang; Barbara A Crane; Jeannette Elliott; Brad E Dicianno; Yih-Kuen Jan
Journal:  Biomed Res Int       Date:  2014-06-26       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.