Literature DB >> 14760859

On-column complexation capillary electrophoretic separation of Fe2+ and Fe3+ using 2,6-pyridinedicarboxylic acid coupled with large-volume sample stacking.

ZuLiang Chen1, Ravendra Naidu.   

Abstract

On-column complexation of Fe2+ and Fe3+ with 2,6-pyridinedicarboxylic acid (2,6-PDCA) formed anionic complexes, which were then separated by capillary zone electrophoresis with direct UV detection at 214 nm. To achieve reasonable separation selectivity and on-column complexation, the conditions such as pH, the concentration of 2,6-PCDA and the EOF modifiers in the electrolyte were examined. The electrolyte contained 5.0 mM 2,6-PDCA, 0.25 mM tetradecyltrimethlammonium bromide (TTAB) and 5% (v/v) acetonitrile at pH 4.0 was optimised for on-column complexation and the separation of Fe[PCDA]2(2-) and Fe[PCDA]2(-). To enhance the detection sensitivity, large-volume sample stacking (LVSS) was used for the on-line preconcentration of Fe[PCDA]2(2-) and Fe[PCDA]2(-). Under the optimised conditions, satisfactory working ranges (0.5-50 microM), lower detection limits (less than 0.1 microM) and good repeatability of the peak areas (R.S.D.: 5.2-7.8%, n = 5) was achieved using LVSS (300 s). With LVSS, the detection sensitivity was enhanced more than 50-fold compared to conventional hydrodynamic injection. The proposed method was used successfully for the determination of Fe2+ and Fe3+ in water samples.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14760859     DOI: 10.1016/j.chroma.2003.10.002

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  On-line sample preconcentration using field-amplified stacking injection in microchip capillary electrophoresis.

Authors:  Maojun Gong; Kenneth R Wehmeyer; Patrick A Limbach; Francisco Arias; William R Heineman
Journal:  Anal Chem       Date:  2006-06-01       Impact factor: 6.986

2.  Improving MCE with electrochemical detection using a bubble cell and sample stacking techniques.

Authors:  Qian Guan; Charles S Henry
Journal:  Electrophoresis       Date:  2009-10       Impact factor: 3.535

3.  Characterisation of Crevice and Pit Solution Chemistries Using Capillary Electrophoresis with Contactless Conductivity Detector.

Authors:  Mengyan Nie; Julian A Wharton; Andy Cranny; Nick R Harris; Robert J K Wood; Keith R Stokes
Journal:  Materials (Basel)       Date:  2013-09-30       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.