Literature DB >> 14757347

Design and validation of a computer-based sleep-scoring algorithm.

Rhain P Louis1, James Lee, Richard Stephenson.   

Abstract

A computer-based sleep scoring algorithm was devised for the real time scoring of sleep-wake state in Wistar rats. Electroencephalogram (EEG) amplitude (microV(rms)) was measured in the following frequency bands: delta (delta; 1.5-6 Hz), theta (Theta; 6-10 Hz), alpha (alpha; 10.5-15 Hz), beta (beta; 22-30 Hz), and gamma (gamma; 35-45 Hz). Electromyographic (EMG) signals (microV(rms)) were recorded from the levator auris longus (neck) muscle, as this yielded a significantly higher algorithm accuracy than the spinodeltoid (shoulder) or temporalis (head) muscle EMGs (ANOVA; P=0.009). Data were obtained using either tethers (n=10) or telemetry (n=4). We developed a simple three-step algorithm that categorizes behavioural state as wake, non-rapid eye movement (NREM) sleep, rapid eye movement (REM) sleep, based on thresholds set during a manually-scored 90-min preliminary recording. Behavioural state was assigned in 5-s epochs. EMG amplitude and ratios of EEG frequency band amplitudes were measured, and compared with empirical thresholds in each animal.STEP 1: EMG amplitude greater than threshold? Yes: "active" wake, no: sleep or "quiet" wake. STEP 2: EEG amplitude ratio (delta x alpha)/(beta x gamma) greater than threshold? Yes: NREM, no: REM or "quiet" wake. STEP 3: EEG amplitude ratio Theta(2)/(delta x alpha) greater than threshold? Yes: REM, no: "quiet" wake. The algorithm was validated with one, two and three steps. The overall accuracy in discriminating wake and sleep (NREM and REM combined) using step one alone was found to be 90.1%. Overall accuracy using the first two steps was found to be 87.5% in scoring wake, NREM and REM sleep. When all three steps were used, overall accuracy in scoring wake, NREM and REM sleep was determined to be 87.9%. All accuracies were derived from comparisons with unequivocally-scored epochs from four 90-min recordings as defined by an experienced human rater. The algorithms were as reliable as the agreement between three human scorers (88%).

Entities:  

Mesh:

Year:  2004        PMID: 14757347     DOI: 10.1016/j.jneumeth.2003.09.025

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  38 in total

1.  Improved sleep-wake and behavior discrimination using MEMS accelerometers.

Authors:  Sridhar Sunderam; Nick Chernyy; Nathalia Peixoto; Jonathan P Mason; Steven L Weinstein; Steven J Schiff; Bruce J Gluckman
Journal:  J Neurosci Methods       Date:  2007-03-15       Impact factor: 2.390

2.  The Dorsal Medial Habenula Minimally Impacts Circadian Regulation of Locomotor Activity and Sleep.

Authors:  Yun-Wei A Hsu; Jennifer J Gile; Jazmine G Perez; Glenn Morton; Miriam Ben-Hamo; Eric E Turner; Horacio O de la Iglesia
Journal:  J Biol Rhythms       Date:  2017-09-27       Impact factor: 3.182

3.  Sleep restriction impairs blood-brain barrier function.

Authors:  Junyun He; Hung Hsuchou; Yi He; Abba J Kastin; Yuping Wang; Weihong Pan
Journal:  J Neurosci       Date:  2014-10-29       Impact factor: 6.167

4.  Non-restraining EEG Radiotelemetry: Epidural and Deep Intracerebral Stereotaxic EEG Electrode Placement.

Authors:  Anna Papazoglou; Andreas Lundt; Carola Wormuth; Dan Ehninger; Christina Henseler; Julien Soós; Karl Broich; Marco Weiergräber
Journal:  J Vis Exp       Date:  2016-06-25       Impact factor: 1.355

5.  Central deficiency of corticotropin-releasing hormone receptor type 1 (CRH-R1) abolishes effects of CRH on NREM but not on REM sleep in mice.

Authors:  Christoph P N Romanowski; Thomas Fenzl; Cornelia Flachskamm; Wolfgang Wurst; Florian Holsboer; Jan M Deussing; Mayumi Kimura
Journal:  Sleep       Date:  2010-04       Impact factor: 5.849

6.  Manual rat sleep classification in principal component space.

Authors:  Timothy P Gilmour; Jidong Fang; Zhiwei Guan; Thyagarajan Subramanian
Journal:  Neurosci Lett       Date:  2009-11-26       Impact factor: 3.046

7.  A non-invasive technique to monitor wakefulness during electrophysiologic recording experiments in primates.

Authors:  Olivier Darbin; Otis Smart; Thomas Wichmann
Journal:  J Neurosci Methods       Date:  2008-11-07       Impact factor: 2.390

8.  Sleep deprivation in pigeons and rats using motion detection.

Authors:  Sarah M Newman; Elliott M Paletz; William H Obermeyer; Ruth M Benca
Journal:  Sleep       Date:  2009-10       Impact factor: 5.849

9.  Sleep-promoting action of IIK7, a selective MT2 melatonin receptor agonist in the rat.

Authors:  Simon P Fisher; David Sugden
Journal:  Neurosci Lett       Date:  2009-04-07       Impact factor: 3.046

10.  Conditional corticotropin-releasing hormone overexpression in the mouse forebrain enhances rapid eye movement sleep.

Authors:  M Kimura; P Müller-Preuss; A Lu; E Wiesner; C Flachskamm; W Wurst; F Holsboer; J M Deussing
Journal:  Mol Psychiatry       Date:  2009-05-19       Impact factor: 15.992

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.