Literature DB >> 14757342

A multichannel telemetry system for single unit neural recordings.

Iyad Obeid1, Miguel A L Nicolelis, Patrick D Wolf.   

Abstract

We present the design, testing, and evaluation of a 16 channel wearable telemetry system to facilitate multichannel single unit recordings from freely moving test subjects. Our design is comprised of (1) a 16-channel analog front end board to condition and sample signals derived from implanted neural electrodes, (2) a digital board for processing and buffering the digitized waveforms, and (3) an index-card sized 486 PC equipped with an IEEE 802.11b wireless ethernet card. Digitized data (up to 12 bits of resolution at 31.25k samples/s per channel) is transferred to the PC and sent to a nearby host computer on a wireless local area network. Up to 12 of the 16 channels were transmitted simultaneously for sustained periods at a range of 9 m. The device measures 5.1 cm x 8.1 cm x 12.4 cm, weighs 235 g, and is powered from rechargeable lithium ion batteries with a lifespan of 45 min at maximum transmission power. The device was successfully used to record signals from awake, chronically implanted macaque and owl monkeys.

Entities:  

Mesh:

Year:  2004        PMID: 14757342     DOI: 10.1016/j.jneumeth.2003.09.023

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  8 in total

Review 1.  Autonomous head-mounted electrophysiology systems for freely behaving primates.

Authors:  Vikash Gilja; Cindy A Chestek; Paul Nuyujukian; Justin Foster; Krishna V Shenoy
Journal:  Curr Opin Neurobiol       Date:  2010-07-23       Impact factor: 6.627

2.  A low noise remotely controllable wireless telemetry system for single-unit recording in rats navigating in a vertical maze.

Authors:  Hsin-Yung Chen; Jin-Shang Wu; Brian Hyland; Xiao-Dong Lu; Jia Jin Jason Chen
Journal:  Med Biol Eng Comput       Date:  2008-05-29       Impact factor: 2.602

3.  Encoding of coordinated grasp trajectories in primary motor cortex.

Authors:  Maryam Saleh; Kazutaka Takahashi; Yali Amit; Nicholas G Hatsopoulos
Journal:  J Neurosci       Date:  2010-12-15       Impact factor: 6.167

4.  Biomedical signal acquisition with streaming wireless communication for recording evoked potentials.

Authors:  Johnson Thie; Alexander Klistorner; Stuart L Graham
Journal:  Doc Ophthalmol       Date:  2012-07-31       Impact factor: 2.379

5.  A fully implantable 96-channel neural data acquisition system.

Authors:  Michael Rizk; Chad A Bossetti; Thomas A Jochum; Stephen H Callender; Miguel A L Nicolelis; Dennis A Turner; Patrick D Wolf
Journal:  J Neural Eng       Date:  2009-03-02       Impact factor: 5.379

6.  A wireless recording system that utilizes Bluetooth technology to transmit neural activity in freely moving animals.

Authors:  Robert E Hampson; Vernell Collins; Sam A Deadwyler
Journal:  J Neurosci Methods       Date:  2009-06-12       Impact factor: 2.390

7.  Low-power, high data rate transceiver system for implantable prostheses.

Authors:  A R Kahn; E Y Chow; O Abdel-Latief; P P Irazoqui
Journal:  Int J Telemed Appl       Date:  2011-01-03

8.  Bayes optimal template matching for spike sorting - combining fisher discriminant analysis with optimal filtering.

Authors:  Felix Franke; Rodrigo Quian Quiroga; Andreas Hierlemann; Klaus Obermayer
Journal:  J Comput Neurosci       Date:  2015-02-05       Impact factor: 1.621

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.