Building characteristics, indoor air quality and recurrent wheezing in very young children (BAMSE).

G Emenius1, M Svartengren, J Korsgaard, L Nordvall, G Pershagen, M Wickman.   

Abstract

This study was conducted to examine the impact of building characteristics and indoor air quality on recurrent wheezing in infants. We followed a birth cohort (BAMSE) comprising 4089 children, born in predefined areas of Stockholm, during their first 2 years of life. Information on exposures was obtained from parental questionnaires when the children were 2 months and on symptoms and diseases when the children were 1 and 2 years old. Children with recurrent wheezing, and two age-matched controls per case, were identified and enrolled in a nested case-control study. The homes were investigated and ventilation rate, humidity, temperature and NO2 measured. We found that living in an apartment erected after 1939, or in a private home with crawl space/concrete slab foundation were associated with an increased risk of recurrent wheezing, odds ratio (OR) 2.5 (1.3-4.8) and 2.5 (1.1-5.4), respectively. The same was true for living in homes with absolute indoor humidity >5.8 g/kg, OR 1.7 (1.0-2.9) and in homes where windowpane condensation was consistently reported over several years, OR 2.2 (1.1-4.5). However, air change rate and type of ventilation system did not seem to affect the risk. In conclusion, relatively new apartment buildings, single-family homes with crawl space/concrete slab foundation, elevated indoor humidity, and reported wintertime windowpane condensation were associated with recurrent wheezing in infants. Thus, improvements of the building quality may have potential to prevent infant wheezing.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14756844     DOI: 10.1046/j.1600-0668.2003.00207.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  11 in total

Review 1.  Autoimmune/inflammatory syndrome induced by adjuvants (ASIA): clues and pitfalls in the pediatric background.

Authors:  Susanna Esposito; Elisabetta Prada; Maria Vincenza Mastrolia; Giusyda Tarantino; Claudio Codecà; Donato Rigante
Journal:  Immunol Res       Date:  2014-12       Impact factor: 2.829

2.  Are building-level characteristics associated with indoor allergens in the household?

Authors:  Lindsay Rosenfeld; Ginger L Chew; Rima Rudd; Karen Emmons; Luis Acosta; Matt Perzanowski; Dolores Acevedo-García
Journal:  J Urban Health       Date:  2011-02       Impact factor: 3.671

3.  The Paris prospective birth cohort study: which design and who participates?

Authors:  B Clarisse; L Nikasinovic; R Poinsard; J Just; I Momas
Journal:  Eur J Epidemiol       Date:  2007-02-06       Impact factor: 8.082

4.  Evaluation of thermal simulation of households in the metropolitan region of São Paulo, Brazil.

Authors:  A S Nedel; F L T Gonçalves; M R A Cardoso; P T Oyola
Journal:  Ecotoxicology       Date:  2009-07-10       Impact factor: 2.823

5.  Association of indoor nitrogen dioxide exposure with respiratory symptoms in children with asthma.

Authors:  Kathleen Belanger; Janneane F Gent; Elizabeth W Triche; Michael B Bracken; Brian P Leaderer
Journal:  Am J Respir Crit Care Med       Date:  2005-10-27       Impact factor: 21.405

6.  Indoor air quality in green-renovated vs. non-green low-income homes of children living in a temperate region of US (Ohio).

Authors:  Kanistha C Coombs; Ginger L Chew; Christopher Schaffer; Patrick H Ryan; Cole Brokamp; Sergey A Grinshpun; Gary Adamkiewicz; Steve Chillrud; Curtis Hedman; Meryl Colton; Jamie Ross; Tiina Reponen
Journal:  Sci Total Environ       Date:  2016-03-05       Impact factor: 7.963

7.  Exposure assessment in cohort studies of childhood asthma.

Authors:  Victoria H Arrandale; Michael Brauer; Jeffrey R Brook; Bert Brunekreef; Diane R Gold; Stephanie J London; J David Miller; Halûk Özkaynak; Nola M Ries; Malcolm R Sears; Frances S Silverman; Tim K Takaro
Journal:  Environ Health Perspect       Date:  2010-11-16       Impact factor: 9.031

8.  Volatile organic compounds enhance allergic airway inflammation in an experimental mouse model.

Authors:  Ulrike Bönisch; Alexander Böhme; Tibor Kohajda; Iljana Mögel; Nicole Schütze; Martin von Bergen; Jan C Simon; Irina Lehmann; Tobias Polte
Journal:  PLoS One       Date:  2012-07-03       Impact factor: 3.240

9.  Respiratory Illness and Allergy Related to Work and Home Environment among Commercial Pilots.

Authors:  Xi Fu; Torsten Lindgren; Gunilla Wieslander; Christer Janson; Dan Norbäck
Journal:  PLoS One       Date:  2016-10-14       Impact factor: 3.240

10.  Chloroanisoles and Chlorophenols Explain Mold Odor but Their Impact on the Swedish Population Is Attributed to Dampness and Mold.

Authors:  Johnny C Lorentzen; Stephanie A Juran; Lena Ernstgård; Mats J Olsson; Gunnar Johanson
Journal:  Int J Environ Res Public Health       Date:  2020-02-03       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.