Literature DB >> 14755754

Comparison of ThinPrep and conventional preparations in pancreatic fine-needle aspiration biopsy.

Regina de Luna1, Mohamad A Eloubeidi, Matthew V Sheffield, Isam Eltoum, Nirag Jhala, Darshana Jhala, Victor K Chen, David C Chhieng.   

Abstract

Use of ThinPrep preparation for fine-needle aspiration biopsy (FNA) is gaining popularity. However, there may be a difference in the morphology and the operating characteristics between ThinPrep and conventional methods. The objective of this study was to compare the accuracy of the two methods and to address the pitfalls of ThinPrep preparation in pancreatic FNA. A computer search identified 67 pancreatic FNAs with both conventional smears and ThinPrep preparation during a 19-mo period. These cases, obtained under endoscopic ultrasound-guidance, consisted of 47 malignant neoplasms (44 ductal carcinomas, two mucinous neoplasms, and one islet cell tumor) and 20 benign lesions. Direct smears were prepared first and the remaining material was then put into PreservCyt Solution for ThinPrep slides. All slides were reviewed and the cytologic diagnoses were correlated with histologic and clinical follow-up. Five conventional and 16 ThinPrep specimens were unsatisfactory due to insufficient cellularity. These cases were excluded from the analysis. Among the 62 cases evaluated by conventional preparation, 77% (34) were diagnosed as positive and 14% (seven) atypical/suspicious by conventional smears. For the 51 ThinPrep specimens, 58% (22) were interpreted as positive and 31% (12) atypical/suspicious. The sensitivity, specificity, and accuracy of diagnosing a malignancy were 77%, 100%, and 84% for conventional smears and 58%, 100%, and 67% for ThinPrep preparation, respectively. There were no false positives with either method. However, three benign lesions were interpreted as atypical/suspicious with ThinPrep preparation because of the presence of single atypical cells with distinct nucleoli. One of the two mucinous neoplasms was incorrectly diagnosed with ThinPrep preparation because of lack of mucin. The diagnostic accuracy of pancreatic FNA using ThinPrep is inferior to that of conventional smears. This may be partly due to the use of split sample technique resulting in scant cellularity in ThinPrep preparation and partly due to the differences in morphology between the two preparations. Therefore, the current morphologic criteria may need modification for ThinPrep preparation in pancreatic FNA. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 14755754     DOI: 10.1002/dc.10349

Source DB:  PubMed          Journal:  Diagn Cytopathol        ISSN: 1097-0339            Impact factor:   1.582


  5 in total

1.  Liquid-based cytology in the fine needle aspiration of parathyroid lesions: a comparison study with the conventional smear, ThinPrep, and SurePath.

Authors:  Gyeong Sin Park; Sung Hak Lee; So Lyung Jung; Chan Kwon Jung
Journal:  Int J Clin Exp Pathol       Date:  2015-10-01

2.  Diagnostic yield and agreement on fine-needle specimens from solid pancreatic lesions : comparing the smear technique to liquid-based cytology.

Authors:  Priscilla A van Riet; Rutger Quispel; Djuna L Cahen; Mieke C Snijders-Kruisbergen; Petri van Loenen; Nicole S Erler; Jan-Werner Poley; Lydi M J W van Driel; Sanna A Mulder; Bart J Veldt; Ivonne Leeuwenburgh; Marie-Paule G F Anten; Pieter Honkoop; Annemieke Y Thijssen; Lieke Hol; Mohammed Hadithi; Claire E Fitzpatrick; Ingrid Schot; Jilling F Bergmann; Abha Bhalla; Marco J Bruno; Katharina Biermann
Journal:  Endosc Int Open       Date:  2020-01-22

Review 3.  The usefulness of liquid-based cytology for endoscopic ultrasound-guided tissue acquisition of solid pancreatic masses.

Authors:  Masahiro Itonaga; Reiko Ashida; Masayuki Kitano
Journal:  Front Med (Lausanne)       Date:  2022-08-16

Review 4.  Present status and perspectives of endosonography 2017 in gastroenterology.

Authors:  Michael Hocke; Barbara Braden; Christian Jenssen; Christoph F Dietrich
Journal:  Korean J Intern Med       Date:  2017-11-23       Impact factor: 2.884

5.  Comparison between Conventional Smear and Liquid-Based Preparation in Endoscopic Ultrasonography-Fine Needle Aspiration Cytology of Pancreatic Lesions.

Authors:  Soo Hee Ko; Jung-Soo Pyo; Byoung Kwan Son; Hyo Young Lee; Il Whan Oh; Kwang Hyun Chung
Journal:  Diagnostics (Basel)       Date:  2020-05-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.