Literature DB >> 14755654

Detection of simulated pulmonary embolism in a porcine model using hyperpolarized 3He MRI.

Aman Jalali1, Masaru Ishii, Johan M Edvinsson, Liang Guan, Maxim Itkin, David A Lipson, James E Baumgardner, Rahim R Rizi.   

Abstract

Several radiological imaging modalities are available to assist with the clinical diagnosis of pulmonary embolism (PE). The most frequently used techniques-nuclear medicine ventilation-perfusion (VP) scan, computed tomography (CT), magnetic resonance angiography (MRA), and pulmonary angiography (PA)-all have literature-supported, substantial limitations with respect to timeliness and patient safety. Hyperpolarized 3He magnetic resonance gas distribution imaging (HP 3He MRI) recently has shown potential as a safer and faster alternative. In this study, we performed HP 3He MRI on a porcine model (N = 6) of simulated PE using selective occlusion balloon catheterization (N = 4) and nonselective aged autologous clot injection (N = 1). The technique was also performed on a normal pig and again after the animal was killed. Temporal depletion of regional HP 3He MRI signal intensity provided for a qualitative assessment of simulated PE (N = 4), and regional PAO2 (alveolar partial pressure of oxygen) was calculated in affected airspaces for a quantitative assessment of simulated PE (N = 1). The preliminary results suggest that HP (3)He MRI shows promise as a means of assessing regional pulmonary perfusion abnormalities in the porcine models of simulated PE that were used in this study. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14755654     DOI: 10.1002/mrm.10698

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  A Constant-Volume Ventilator and Gas Recapture System for Hyperpolarized Gas MRI of Mouse and Rat Lungs.

Authors:  John Nouls; Manuel Fanarjian; Laurence Hedlund; Bastiaan Driehuys
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2011-04       Impact factor: 1.176

Review 2.  Imaging of lung function using hyperpolarized helium-3 magnetic resonance imaging: Review of current and emerging translational methods and applications.

Authors:  Sean Fain; Mark L Schiebler; David G McCormack; Grace Parraga
Journal:  J Magn Reson Imaging       Date:  2010-12       Impact factor: 4.813

3.  A variability study of regional alveolar oxygen tension measurement in humans using hyperpolarized (3) He MRI.

Authors:  Hooman Hamedani; Stephen J Kadlecek; Masaru Ishii; Kiarash Emami; Nicholas N Kuzma; Yi Xin; Milton Rossman; Rahim R Rizi
Journal:  Magn Reson Med       Date:  2013-02-04       Impact factor: 4.668

Review 4.  [Functional 3He-MRI of the lungs].

Authors:  K K Gast; U Wolf
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

5.  A short-breath-hold technique for lung pO2 mapping with 3He MRI.

Authors:  G Wilson Miller; John P Mugler; Talissa A Altes; Jing Cai; Jaime F Mata; Eduard E de Lange; William A Tobias; Gordon D Cates; James R Brookeman
Journal:  Magn Reson Med       Date:  2010-01       Impact factor: 4.668

  5 in total