Literature DB >> 14753712

Simultaneous determination of twelve inorganic and organic arsenic compounds by liquid chromatography-ultraviolet irradiation-hydride generation atomic fluorescence spectrometry.

Stéphane Simon1, Huong Tran, Florence Pannier, Martine Potin-Gautier.   

Abstract

A coupling between column liquid chromatography (LC) and atomic fluorescence spectrometry was developed for arsenic speciation. After separation, the compounds are oxidised on-line by UV irradiation, volatilised by hydride-generation and carried to the detector by a stream of argon. A combination of anion-exchange and hydrophobic interactions in a single column (Dionex AS7) was found suitable for the simultaneous separation of organic and inorganic species. Twelve compounds (arsenite, arsenate, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine, arsenocholine, trimethylarsine oxide, tetramethylarsonium ion and four arsenosugars) were separated using an acetate buffer and a nitric acid solution as mobile phases. Limits of detection are 4-22 pg. The technique was applied to three marine samples. Arsenobetaine was detected as the main species in all samples, with concentrations varying from 59 to 1947 ng(As) g(-1) of fresh mass.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14753712     DOI: 10.1016/j.chroma.2003.09.068

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

Review 1.  Arsenic speciation analysis in water samples: a review of the hyphenated techniques.

Authors:  Ewa Terlecka
Journal:  Environ Monit Assess       Date:  2005-08       Impact factor: 2.513

2.  Design and development of an automated flow injection instrument for the determination of arsenic species in natural waters.

Authors:  Grady Hanrahan; Tina K Fan; Melanie Kantor; Keith Clark; Steven Cardenas; Darrell W Guillaume; Crist S Khachikian
Journal:  Rev Sci Instrum       Date:  2009-10       Impact factor: 1.523

3.  Speciation Analysis of Arsenic Compounds by High-Performance Liquid Chromatography in Combination with Inductively Coupled Plasma Dynamic Reaction Cell Quadrupole Mass Spectrometry: Application for Vietnamese Rice Samples.

Authors:  Hai Anh Vu; Manh Ha Nguyen; Hong-An Vu-Thi; Quan Do-Hong; Xuan Hoang Dang; Thi Ngoc Bich Nguyen; Hong Quan Trinh; Thuy Ly Bich; Tien-Thanh Nguyen; Dung Le-Van; Minh Binh Tu; Dinh Binh Chu
Journal:  J Anal Methods Chem       Date:  2019-04-28       Impact factor: 2.193

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.