Literature DB >> 14753331

Thermal and mechanical load cycling on microleakage and shear bond strength to dentin.

Ana Karina Barbieri Bedran-de-Castro1, Paulo Eduardo Capel Cardoso, Glaucia Maria Boni Ambrosano, Luiz André Freire Pimenta.   

Abstract

This study evaluated the influence of mechanical and thermal cycling on microleakage at the cervical margins of proximal slot restorations and shear bond strength on flat dentin surfaces. Microleakage Evaluation: One hundred and twenty slot cavity restorations were performed on bovine incisors. The restorations were randomly divided into four groups (n = 30): control (no thermal and mechanical load cycling), thermal cycling (2,000 cycles, 5 degrees C-55 degrees C), mechanical load cycling (50,000-80N) and thermal and load cycling (2,000 5 degrees C-55 degrees C/50,000-80N). The specimens were sealed with acid resistant varnish, leaving a 1-mm window around the cervical margin interface. To detect marginal leakage, a 2% methylene blue buffered solution was used for four hours. The specimens were sectioned longitudinally and qualitatively evaluated by stereomicroscopy (45x) following a ranked score for the dentin cervical margin. The data were analyzed by Kruskal-Wallis test (alpha = 0.05). Shear Bond Strength Evaluation (SBS): Eighty bovine incisors were embedded and polished to obtain a flat standard surface on dentin. The surfaces were restored with Single Bond adhesive system and a resin composite subsequently inserted in a bipartite Teflon matrix. The specimens were randomly divided into the four groups (n = 20) described above for microleakage. Shear bond strengths were measured in a universal testing machine with a crosshead speed of 0.5 mm/minute. The data were analyzed by one way ANOVA test (alpha = 0.05). No statistically significant influence of thermocycling, mechanical load cycling or the combination was observed for both microleakage and shear bond strength.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14753331

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  3 in total

1.  Micro-CT evaluation of microleakage under orthodontic ceramic brackets bonded with different bonding techniques and adhesives.

Authors:  Fırat Öztürk; Mustafa Ersöz; Seyit Ahmet Öztürk; Erdem Hatunoğlu; Sıddık Malkoç
Journal:  Eur J Orthod       Date:  2015-04-08       Impact factor: 3.075

2.  Indirect resin composites.

Authors:  Suresh Nandini
Journal:  J Conserv Dent       Date:  2010-10

3.  Comparison of demineralization around orthodontic brackets cured by conventional method and transillumination technique-an in vitro evaluation.

Authors:  Monis Raza; Piush Kumar; Nikita Gulati; Payal Sharma; Divya Shetty; Devicharan Shetty
Journal:  J Orthod Sci       Date:  2020-11-02
  3 in total