Literature DB >> 14751574

Detecting and tracking local changes in the tibiae of individual rats: a novel method to analyse longitudinal in vivo micro-CT data.

J H Waarsing1, J S Day, J C van der Linden, A G Ederveen, C Spanjers, N De Clerck, A Sasov, J A N Verhaar, H Weinans.   

Abstract

In this study we present the analysis of in vivo micro-CT scans using a new method based on image registration that accurately evaluates longitudinal micro-CT studies. We tested if detailed changes in the bone architecture could be detected and tracked in individual animals. A prototype in vivo micro-CT scanner (Skyscan 1076) was developed in which tibiae of rats that are lying on a bed under gas anaesthesia were scanned. For this study, three female Wistar rats were used: a sham-operated rat, an ovariectomised (OVX) rat and one rat that served as a reproducibility control. The reproducibility control rat was scanned twice in 1 day. The other animals were scanned at week 0, just before surgery, at week 4 and at week 14 after surgery. Architectural changes over time were detected by overlaying two data sets made at different time points using an algorithm that uses mutual information for optimal registration. The scans were segmented into binary data sets using a local thresholding algorithm. The reproducibility test showed small errors of less than 3% in bone volume measurements and errors less than 0.5% in measurements of trabecular thickness. The sham-operated rat showed no changes in total bone volume, though thinning and eventual loss of some small trabeculae could be detected, which could be related to the age of the animal. The OVX rat lost much trabecular bone volume, especially in the metaphysis (60% at week 4, 75% at week 14). The remaining trabeculae slowly increased in thickness. Following the different scans in time showed the forming of new trabecular structures. Additionally, small longitudinal growth at the growth plate could be detected after the first 4 weeks. Further, the OVX rat showed extensive modelling at the proximal endosteal lateral cortex. We have shown a new method that can detect and track changes in the local bone architecture and individual trabeculae in time, in an individual living animal. This method enables longitudinal in vivo micro-CT studies and has the potential to greatly contribute to experimental rat or mouse studies on pharmacological intervention and transgenic models.

Entities:  

Mesh:

Year:  2004        PMID: 14751574     DOI: 10.1016/j.bone.2003.08.012

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  73 in total

1.  Visualization of mouse spinal cord microscopic structures by use of ex vivo quantitative micro-CT images.

Authors:  Shigeyoshi Saito; Kenya Murase
Journal:  Radiol Phys Technol       Date:  2012-06-24

Review 2.  Methods for assessing bone quality: a review.

Authors:  Eve Donnelly
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

3.  High-turnover osteoporosis is induced by cyclosporin A in rats.

Authors:  Chie Wada; Masatoshi Kataoka; Hiroyuki Seto; Noriko Hayashi; Jun-ichi Kido; Yasuo Shinohara; Toshihiko Nagata
Journal:  J Bone Miner Metab       Date:  2006       Impact factor: 2.626

Review 4.  Effects of microarchitecture on bone strength.

Authors:  Jacqueline C van der Linden; Harrie Weinans
Journal:  Curr Osteoporos Rep       Date:  2007-06       Impact factor: 5.096

5.  Study of subchondral bone adaptations in a rodent surgical model of OA using in vivo micro-computed tomography.

Authors:  D D McErlain; C T G Appleton; R B Litchfield; V Pitelka; J L Henry; S M Bernier; F Beier; D W Holdsworth
Journal:  Osteoarthritis Cartilage       Date:  2007-09-27       Impact factor: 6.576

6.  The effects of loading on cancellous bone in the rabbit.

Authors:  Marjolein C H van der Meulen; Xu Yang; Timothy G Morgan; Mathias P G Bostrom
Journal:  Clin Orthop Relat Res       Date:  2009-05-21       Impact factor: 4.176

7.  Evaluation of the effects of photobiomodulation on vertebras in two rat models of experimental osteoporosis.

Authors:  Mohammadjavad Fredoni; Mahdi Ghatrehsamani; Mohammad-Amin Abdollahifar; Sahar Bayat; Mohammad Bayat
Journal:  Lasers Med Sci       Date:  2017-07-19       Impact factor: 3.161

8.  In vivo micro-CT scanning of a rabbit distal femur: repeatability and reproducibility.

Authors:  Michael J Voor; Shuo Yang; Robert L Burden; Seid W Waddell
Journal:  J Biomech       Date:  2007-08-22       Impact factor: 2.712

9.  Time course of rapid bone loss and cortical porosity formation observed by longitudinal μCT in a rat model of CKD.

Authors:  Erin M B McNerny; Dorothy T Buening; Mohammad W Aref; Neal X Chen; Sharon M Moe; Matthew R Allen
Journal:  Bone       Date:  2019-05-03       Impact factor: 4.398

10.  High-resolution X-ray microtomography for the detection of lung tumors in living mice.

Authors:  Nora M De Clerck; Kris Meurrens; Horst Weiler; Dirk Van Dyck; Greet Van Houtte; Piter Terpstra; Andrei A Postnov
Journal:  Neoplasia       Date:  2004 Jul-Aug       Impact factor: 5.715

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.