Literature DB >> 14750380

Core needle biopsy of palpable breast lump: the influence of needle size.

T E Wong1, A N Hisham.   

Abstract

The diagnostic value of core needle biopsy is increasingly being preferred because of its better characterization of benign and malignant lesions and lower frequency of insufficient samples. The aim of this study was to determine the diagnostic accuracy and complication rates with 2 different gauges of core biopsy needle in the preoperative diagnosis of palpable breast lumps. A total of 150 consecutive core biopsies were included in this prospective non-randomised study of palpable breast lump from May 2000 to May 2001. The tissue diagnosis made from the core biopsy specimen was compared with the final histopathology reports from the excised specimen. However, if the lump is not excised, a presumptive diagnosis of benign lesion was made only after at least 6 months follow up with no change in the breast lump. The data were analysed for sensitivity, specificity, predictive values, diagnostic accuracy and complications. The results from the 2 different sizes of core needle biopsies were compared accordingly and a statistical analysis was performed using Chi-squared test. Ninety-six core specimens were acquired with 14 G needle while the other 54 with 16 G needle. There was no significant statistical difference between the accuracy of both needle sizes. However, 4 complications occurred with the larger size 14 G needle while none with the 16 G needle, but this was not statistically significant. In conclusion the size 16 G core biopsy needle provided an accurate diagnostic reliability that is comparable to the larger size 14 G needle in the preoperative diagnosis of palpable breast lump.

Entities:  

Mesh:

Year:  2003        PMID: 14750380

Source DB:  PubMed          Journal:  Med J Malaysia        ISSN: 0300-5283


  3 in total

Review 1.  An overview of assessment of prognostic and predictive factors in breast cancer needle core biopsy specimens.

Authors:  E A Rakha; I O Ellis
Journal:  J Clin Pathol       Date:  2007-07-14       Impact factor: 3.411

2.  Diagnostic usefulness of tru-cut biopsy in the diagnosis of breast lesions.

Authors:  Ammar Rikabi; Sufia Hussain
Journal:  Oman Med J       Date:  2013-03

3.  Core biopsy as a tool in planning the management of invasive breast cancer.

Authors:  Amar Deshpande; Trivikram Garud; Simon D Holt
Journal:  World J Surg Oncol       Date:  2005-01-04       Impact factor: 2.754

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.