Literature DB >> 14749084

Role of mechanical environment and implant design on bone tissue differentiation: current knowledge and future contexts.

Murat Cehreli1, Saime Sahin, Kivanç Akça.   

Abstract

OBJECTIVES: To evaluate published evidence related to bone reactions to varying loading regimens and the impact of implant design on bone tissue differentiation. DATA AND SOURCES: The literature was searched for original research articles relating effect of mechanical environment on bone tissue and effects of implant design on bone biomechanics and marginal bone reactions using MEDLINE and manual tracing of references cited in key papers otherwise not elicited. STUDY SELECTION: Current literature on biomechanics of bone and dental implants as main focus and pertinent to key aspects of the review.
CONCLUSIONS: Implant design influences force transmission characteristics in peri-implant bone, but not the time-dependent marginal bone reactions. Mechanical signals affect bone tissue differentiation. Therefore, it is essential to control biomechanical loads on implants to maintain osseointegration and/or to promote early bone-implant interface healing.

Mesh:

Substances:

Year:  2004        PMID: 14749084     DOI: 10.1016/j.jdent.2003.09.003

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  14 in total

1.  Stress distribution on a three-unit implant-supported zirconia framework. A 3D finite element analysis and fatigue test.

Authors:  G Sannino; A Pozzi; R Schiavetti; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2012-07-17

2.  Biomechanical consequences of progressive marginal bone loss around oral implants: a finite element stress analysis.

Authors:  Kivanc Akca; Murat Cavit Cehreli
Journal:  Med Biol Eng Comput       Date:  2006-06-10       Impact factor: 2.602

3.  Is the presence of keratinized mucosa associated with periimplant tissue health? A clinical cross-sectional analysis.

Authors:  Catharina Ladwein; Rainer Schmelzeisen; Katja Nelson; Tabea Viktoria Fluegge; Tobias Fretwurst
Journal:  Int J Implant Dent       Date:  2015-04-29

4.  In vitro comparison of primary stability of two implant designs in D3 bone.

Authors:  J González-Serrano; R Ortega-Aranegui; J López-Quiles
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-07-01

5.  Machined and plastic copings in three-element prostheses with different types of implant-abutment joints: a strain gauge comparative analysis.

Authors:  Renato Sussumu Nishioka; Lea Nogueira Braulino de Melo Nishioka; Celina Wanderley Abreu; Luis Gustavo Oliveira de Vasconcellos; Ivan Balducci
Journal:  J Appl Oral Sci       Date:  2010 May-Jun       Impact factor: 2.698

6.  Anatomical Thin Titanium Mesh Plate Structural Optimization for Zygomatic-Maxillary Complex Fracture under Fatigue Testing.

Authors:  Yu-Tzu Wang; Shao-Fu Huang; Yu-Ting Fang; Shou-Chieh Huang; Hwei-Fang Cheng; Chih-Hao Chen; Po-Fang Wang; Chun-Li Lin
Journal:  Biomed Res Int       Date:  2018-05-20       Impact factor: 3.411

7.  Influence of different restorative materials on the stress distribution in dental implants.

Authors:  Carlos-Eduardo Datte; João-Paulo-Mendes Tribst; Amanda-Maria-de Oliveira Dal Piva; Renato-Sussumu Nishioka; Marco-Antonio Bottino; Alexandre-Duarte M Evangelhista; Fabrício M de M Monteiro; Alexandre-Luiz-Souto Borges
Journal:  J Clin Exp Dent       Date:  2018-05-01

8.  Micro-morphologic changes around biophysically-stimulated titanium implants in ovariectomized rats.

Authors:  Kivanc Akca; Ebru Sarac; Ugur Baysal; Mete Fanuscu; Ting-Ling Chang; Murat Cehreli
Journal:  Head Face Med       Date:  2007-07-16       Impact factor: 2.151

9.  Comparative evaluation of osseointegrated dental implants based on platform-switching concept: influence of diameter, length, thread shape, and in-bone positioning depth on stress-based performance.

Authors:  Luigi Baggi; Michele Di Girolamo; Giuseppe Vairo; Gianpaolo Sannino
Journal:  Comput Math Methods Med       Date:  2013-06-19       Impact factor: 2.238

10.  Influence of short implants geometry on primary stability.

Authors:  J González-Serrano; P Molinero-Mourelle; B Pardal-Peláez; L-M Sáez-Alcaide; R Ortega; J López-Quiles
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2018-09-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.