Model of total skin electron treatment using the 'six-dual-field' technique.

Dario Faj1, Mladen Vrtar, Zdenko Krajina, Slaven Jurković, Damir Margaretić.   

Abstract

During implementation of the total skin electron treatment, using six-dual-field technique, at radiotherapy department a large number of measurements are needed. To assess depth dose curve required by clinicians and dose uniformity over a whole treatment plane, combinations of different irradiation parameters are used (electron energy, beam angle, scatterers). Measurements for each combination must be performed. One possible way to reduce number of measurements is to model the treatment using the Monte Carlo simulation of electron transport. We made a simplified multiple-source Monte Carlo model of electron beam and tested it by comparing calculations and experimental results. Calculated data differs less than 5 percent from measurements in the treatment plane. During the treatment patient can be approximated using cylinders with different diameters and orientations. We tried to model the depth dose variations in the total skin electron treatment not just around the body cross-section (simplified to cylinders of different diameters), but also along the body to account for the variations in body curvature longitudinally. This effect comes down to the problem of modeling distribution in different cylinders, but varying the longitudinal orientation of those cylinders. We compared Monte Carlo calculations and film measurements of depth dose curves for two orientations of the cylindrical phantom, which were the simplest for experimental arrangement. Comparison of the results proved accuracy of the model and we used it to calculate depth dose curves for a number of other cylinder orientations.

Entities:  

Mesh:

Year:  2003        PMID: 14746163

Source DB:  PubMed          Journal:  Coll Antropol        ISSN: 0350-6134


  3 in total

1.  Advantages and implications of high dose rate (HDR) total skin electron irradiation (TSEI) for the management of Mycosis Fungoides. Indian experience.

Authors:  Dillip Kumar Parida; Goura Kishore Rath
Journal:  Rep Pract Oncol Radiother       Date:  2013-08-28

2.  Dosimetric verification of compensated beams using radiographic film.

Authors:  Slaven Jurkovic; Gordana Zauhar; Dario Faj; Deni Smilovic Radojcic; Manda Svabic; Mladen Kasabasic; Ana Diklic
Journal:  Radiol Oncol       Date:  2011-07-20       Impact factor: 2.991

3.  Validation of total skin electron irradiation (TSEI) technique dosimetry data by Monte Carlo simulation.

Authors:  Alexander Nevelsky; Egor Borzov; Shahar Daniel; Rachel Bar-Deroma
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.