Literature DB >> 14741588

Chronic response of adult rat brain tissue to implants anchored to the skull.

Young-Tae Kim1, Robert W Hitchcock, Michael J Bridge, Patrick A Tresco.   

Abstract

Using quantitative immunohistological methods, we examined the brain tissue response to hollow fiber membranes (HFMs) that were either implanted intraparenchymally, as in a cell encapsulation application, or were attached to the skull as in a biosensor application (transcranially). We found that the reaction surrounding transcranially implanted HFMs was significantly greater than that observed with intraparenchymally implanted materials including increases in immunoreactivity against GFAP, vimentin, ED-1 labeled macrophages and microglia, and several extracellular matrix proteins including collagen, fibronectin, and laminin. In general, these markers were elevated along the entire length of transcranially implanted HFMs extending into the adjacent parenchyma up to 0.5 mm from the implant interface. Intraparenchymal implants did not appear to have significant involvement of a fibroblastic component as suggested by a decreased expression of vimentin, fibronectin and collagen-type I at the implant tissue interface. The increase in tissue reactivity observed with transcranially implanted HFMs may be influenced by several mechanisms including chronic contact with the meninges and possibly motion of the device within brain tissue. Broadly speaking, our results suggest that any biomaterial, biosensor or device that is anchored to the skull and in chronic contact with meningeal tissue will have a higher level of tissue reactivity than the same material completely implanted within brain tissue.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14741588     DOI: 10.1016/j.biomaterials.2003.09.010

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  58 in total

1.  Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies.

Authors:  J P Harris; J R Capadona; R H Miller; B C Healy; K Shanmuganathan; S J Rowan; C Weder; D J Tyler
Journal:  J Neural Eng       Date:  2011-11-02       Impact factor: 5.379

2.  Layered nanocomposites from gold nanoparticles for neural prosthetic devices.

Authors:  Huanan Zhang; Jimmy Shih; Jian Zhu; Nicholas A Kotov
Journal:  Nano Lett       Date:  2012-06-26       Impact factor: 11.189

3.  Compliant intracortical implants reduce strains and strain rates in brain tissue in vivo.

Authors:  Arati Sridharan; Jessica K Nguyen; Jeffrey R Capadona; Jit Muthuswamy
Journal:  J Neural Eng       Date:  2015-04-02       Impact factor: 5.379

4.  Insertion of flexible neural probes using rigid stiffeners attached with biodissolvable adhesive.

Authors:  Sarah H Felix; Kedar G Shah; Vanessa M Tolosa; Heeral J Sheth; Angela C Tooker; Terri L Delima; Shantanu P Jadhav; Loren M Frank; Satinderpall S Pannu
Journal:  J Vis Exp       Date:  2013-09-27       Impact factor: 1.355

5.  Intracranial electrode implantation produces regional neuroinflammation and memory deficits in rats.

Authors:  Yafit Kuttner Hirshler; Uri Polat; Anat Biegon
Journal:  Exp Neurol       Date:  2009-12-21       Impact factor: 5.330

6.  Monitoring hippocampus electrical activity in vitro on an elastically deformable microelectrode array.

Authors:  Zhe Yu; Oliver Graudejus; Candice Tsay; Stéphanie P Lacour; Sigurd Wagner; Barclay Morrison
Journal:  J Neurotrauma       Date:  2009-07       Impact factor: 5.269

7.  Inhibition of the cluster of differentiation 14 innate immunity pathway with IAXO-101 improves chronic microelectrode performance.

Authors:  John K Hermann; Madhumitha Ravikumar; Andrew J Shoffstall; Evon S Ereifej; Kyle M Kovach; Jeremy Chang; Arielle Soffer; Chun Wong; Vishnupriya Srivastava; Patrick Smith; Grace Protasiewicz; Jingle Jiang; Stephen M Selkirk; Robert H Miller; Steven Sidik; Nicholas P Ziats; Dawn M Taylor; Jeffrey R Capadona
Journal:  J Neural Eng       Date:  2018-04       Impact factor: 5.379

8.  Intracranial EEG fluctuates over months after implanting electrodes in human brain.

Authors:  Hoameng Ung; Steven N Baldassano; Hank Bink; Abba M Krieger; Shawniqua Williams; Flavia Vitale; Chengyuan Wu; Dean Freestone; Ewan Nurse; Kent Leyde; Kathryn A Davis; Mark Cook; Brian Litt
Journal:  J Neural Eng       Date:  2017-09-01       Impact factor: 5.379

9.  Chronic intracortical microelectrode arrays induce non-uniform, depth-related tissue responses.

Authors:  Andrew J Woolley; Himanshi A Desai; Kevin J Otto
Journal:  J Neural Eng       Date:  2013-02-21       Impact factor: 5.379

10.  An approach for long-term, multi-probe Neuropixels recordings in unrestrained rats.

Authors:  Thomas Zhihao Luo; Adrian Gopnik Bondy; Diksha Gupta; Verity Alexander Elliott; Charles D Kopec; Carlos D Brody
Journal:  Elife       Date:  2020-10-22       Impact factor: 8.140

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.