Literature DB >> 14740700

Left ventricular function during intra-aortic balloon pumping assessed by multigated cardiac blood pool imaging.

A B Nichols1, G M Pohost, H K Gold, R C Leinbach, G A Beller, K A McKusick, H W Strauss, M J Buckley.   

Abstract

The effectiveness of intra-aortic balloon pumping in augmenting ventricular performance during acute myocardial ischemic syndromes was determined by noninvasive multigated cardiac blood pool imaging. Nine patients with unstable angina refractory to medical therapy and nine patients with acute myocardial infarction complicated by congestive heart failure were studied on and off intra-aortic balloon pumping (IABP). End-diastolic and end-systolic volumes were significantly reduced by IABP in both unstable angina and myocardial infarction. Analysis of ventricular wall motion demonstrated improved segmental contraction during IABP in all seven unstable angina patients with regional wall motion abnormalities. No significant improvement in regional contraction was observed in the nine patients with acute myocardial infarction. During IABP, percent ventricular asynergy decreased significantly (28.2%; P < 0.01) among patients with unstable angina but demonstrated no significant fall (4.4%; P = NS) for patients with myocardial infarction. Thus, IABP enhances contraction of ischemic but not infarcted myocardium and effectively improves ventricular function by reducing end-diastolic and end-systolic volumes.

Entities:  

Mesh:

Year:  1978        PMID: 14740700

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  5 in total

Review 1.  Mechanical Circulatory Support for Decompensated Heart Failure.

Authors:  Tarique Al Musa; Colin Dominic Chue; Hoong Sern Lim
Journal:  Curr Heart Fail Rep       Date:  2017-10

Review 2.  IABP: history-evolution-pathophysiology-indications: what we need to know.

Authors:  H Parissis; V Graham; S Lampridis; M Lau; G Hooks; P C Mhandu
Journal:  J Cardiothorac Surg       Date:  2016-08-04       Impact factor: 1.637

3.  Determination of cardiac output from pulse pressure contour during intra-aortic balloon pumping in patients with low ejection fraction.

Authors:  Jos R C Jansen; Marcelo B Bastos; Pat Hanlon; Nicolas M Van Mieghem; Ottavio Alfieri; Jan J Schreuder
Journal:  J Clin Monit Comput       Date:  2019-05-14       Impact factor: 2.502

4.  Benefits of Intra-Aortic Balloon Pump Support in Patients with Postcardiotomy Shock Requiring Venoarterial Extracorporeal Membrane Oxygenation.

Authors:  Dejan Radakovic; Kiril Penov; Khaled Hamouda; Nodir Madrahimov; Darko Radakovic; Constanze Bening; Rainer G Leyh; Ivan Aleksic
Journal:  Life (Basel)       Date:  2022-08-05

5.  Epidural Oscillating Cardiac-Gated Intracranial Implant Modulates Cerebral Blood Flow.

Authors:  Mark G Luciano; Stephen M Dombrowski; Serge El-Khoury; Jun Yang; Suraj Thyagaraj; Sara Qvarlander; Syed Khalid; Ian Suk; Amir Manbachi; Francis Loth
Journal:  Neurosurgery       Date:  2020-11-16       Impact factor: 4.654

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.