Literature DB >> 14740699

Aortocoronary saphenous vein bypass graft changes 5 to 7 years after surgery.

L Campeau1, J Lespérance, F Corbara, J Hermann, C M Grondin, M G Bourassa.   

Abstract

Control angiographic studies were carried out 54 to 88 months after aortocoronary saphenous vein bypass surgery (70 +/- 10 months) in 100 unselected patients who were known to have at least one patent graft 6 to 18 months following the operation. Only 17 of the 159 grafts were found occluded during this interval of 5 years, giving an average yearly attrition rate of 2.1% after the first year. The mean yearly attrition rate was 0.7% in our second series of near consecutive patients operated on after 2 years of experience and modifications of surgical techniques, and it compares favorably with the 2.4% yearly attrition rate found in our first series of patients (P < 0.05). Of the 37 grafts having localized stenoses at 1 year, eight became occluded (21.6%), and four became worse. Grafts with localized stenoses were more prone to late occlusion, whereas no late occlusion was observed in normally appearing grafts at 1 year. Diffuse graft narrowing noted during the first year showed no further change during the subsequent 5 years, and it did not appear to lead to late occlusion. Finally, in 14 grafts, localized narrowing developed after the first year, at a yearly rate of 1.5%. Atherosclerosis appears to be the most likely etiology, being found in two of these instances at reoperation.

Entities:  

Mesh:

Year:  1978        PMID: 14740699

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  3 in total

1.  Protective constriction of coronary vein grafts with knitted nitinol.

Authors:  Loven Moodley; Thomas Franz; Paul Human; Michael F Wolf; Deon Bezuidenhout; Jacques Scherman; Peter Zilla
Journal:  Eur J Cardiothorac Surg       Date:  2013-01-07       Impact factor: 4.191

2.  Diagnostic accuracy of 256-row multidetector CT coronary angiography with prospective ECG-gating combined with fourth-generation iterative reconstruction algorithm in the assessment of coronary artery bypass: evaluation of dose reduction and image quality.

Authors:  Davide Ippolito; Davide Fior; Cammillo Talei Franzesi; Luca Riva; Alessandra Casiraghi; Sandro Sironi
Journal:  Radiol Med       Date:  2017-08-28       Impact factor: 3.469

3.  Evaluation of coronary bypass grafts.

Authors:  H A Torman; D C Levin
Journal:  Cardiovasc Intervent Radiol       Date:  1982       Impact factor: 2.740

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.