Effect of PEEP on the mechanics of the respiratory system in ARDS patients.

N T Eissa1, V M Ranieri, C Corbeil, M Chassé, J Braidy, J Milic-Emili.   

Abstract

In patients with adult respiratory distress syndrome (ARDS) we studied the effect of positive end-expiratory pressure (PEEP) on respiratory mechanics. We used the technique of rapid airway occlusion during constant flow (V) inflation to partition the total respiratory system resistance (Rrs) into the interrupter resistance (Rint,rs) and the additional resistance (delta Rrs) due to viscoelastic pressure dissipations and time constant inequalities. We also measured static (Est,rs) and dynamic (Edyn,rs) elastance of the respiratory system. The procedure was carried out in nine ARDS patients at different inspiratory V and inflation volumes (delta V) at PEEP of 0, 5, 10, and 15 cmH2O. We found that during baseline ventilation (delta V = 0.7 liter and V = 1 l/s), Est,rs, Edyn,rs, and Rint,rs did not change significantly with PEEP, whereas delta Rrs and Rrs increased significantly only with PEEP of 15 cmH2O. The increase of delta Rrs and Rrs with PEEP was positively correlated with the concomitant changes in end-expiratory lung volume (P < 0.001). At all levels of PEEP, under iso-delta V conditions, delta Rrs decreased with increasing V, whereas at a fixed V, delta Rrs increased with increasing delta V. A four-parameter model of the respiratory system failed to fully describe respiratory dynamics in the ARDS patients, probably due to nonlinearities.

Entities:  

Mesh:

Year:  1992        PMID: 1474044     DOI: 10.1152/jappl.1992.73.5.1728

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  3 in total

1.  Sigh: tool to determine the respiratory viscoelastic properties.

Authors:  Vittorio Antonaglia; Alberto Peratoner; Loredana De Simoni; Umberto Lucangelo; Antonino Gullo; Walter A Zin
Journal:  J Clin Monit Comput       Date:  2002-12       Impact factor: 2.502

2.  Pressure-dependent stress relaxation in acute respiratory distress syndrome and healthy lungs: an investigation based on a viscoelastic model.

Authors:  Steven Ganzert; Knut Möller; Daniel Steinmann; Stefan Schumann; Josef Guttmann
Journal:  Crit Care       Date:  2009-12-09       Impact factor: 9.097

3.  Dynamics of regional lung aeration determined by electrical impedance tomography in patients with acute respiratory distress syndrome.

Authors:  Sven Pulletz; Matthias Kott; Gunnar Elke; Dirk Schädler; Barbara Vogt; Norbert Weiler; Inéz Frerichs
Journal:  Multidiscip Respir Med       Date:  2012-11-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.