Literature DB >> 14739406

Parametric perfusion imaging with contrast-enhanced ultrasound in acute ischemic stroke.

Martin Wiesmann1, Karsten Meyer, Thomas Albers, Günter Seidel.   

Abstract

BACKGROUND AND
PURPOSE: Color-coded perfusion maps can be calculated from ultrasound harmonic gray-scale imaging data after ultrasound contrast agent bolus injection to analyze brain tissue perfusion. First reports indicate that this method can display cerebral perfusion deficits in acute ischemic stroke. We performed a prospective patient study to evaluate this approach.
METHODS: Thirty consecutive patients suffering from acute middle cerebral artery infarction who presented to our department within 12 hours after symptom onset were investigated with ultrasound perfusion harmonic imaging (PHI) after Levovist bolus injection. Color-coded perfusion maps were calculated from the ultrasound data. In addition, the original gray-scale images were analyzed in cine mode. Findings were compared with those of cranial CT.
RESULTS: All 30 patients suffered from acute ischemic stroke of the middle cerebral artery territory (median National Institutes of Health Stroke Scale score, 16 points). Twenty-three of the 30 patients (76.7%) had sufficient PHI insonation conditions. In 19 of these 23 patients (82.6%), a marked deficit in contrast enhancement could be visualized by initial PHI with the color-coded parameter images and cine-mode images. In 17 of the 23 (73.9%), the perfusion deficit was found on the parameter images. The area of hypoperfusion in the initial PHI investigation corresponded to the definite area of infarction in follow-up cranial CT. In 3 of 23 patients (13.0%), a perfusion deficit could be demonstrated in PHI, although the supplying artery was found patent by transcranial color-coded duplex sonography.
CONCLUSIONS: With PHI, it is possible to display cerebral perfusion deficits in acute ischemic stroke. PHI yields additional information on the perfusion state of the human brain compared with extracranial and transcranial color-coded duplex sonography.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14739406     DOI: 10.1161/01.STR.0000114877.58809.3D

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  16 in total

1.  Assessment of tissue perfusion by contrast-enhanced ultrasound.

Authors:  Emilio Quaia
Journal:  Eur Radiol       Date:  2010-10-07       Impact factor: 5.315

Review 2.  Leveraging the power of ultrasound for therapeutic design and optimization.

Authors:  Charles F Caskey; Xiaowen Hu; Katherine W Ferrara
Journal:  J Control Release       Date:  2011-07-30       Impact factor: 9.776

Review 3.  [Vascular imaging with contrast-enhanced sonography for experimental use].

Authors:  M Krix; H-U Kauczor; S Delorme
Journal:  Radiologe       Date:  2005-06       Impact factor: 0.635

4.  Transcranial contrast-enhanced ultrasonography with Sonazoid in semiquantitative evaluation of brain perfusion.

Authors:  Kozue Saito; Toshiko Hirai; Satoshi Ueno
Journal:  J Med Ultrason (2001)       Date:  2013-02-28       Impact factor: 1.314

5.  Parametric imaging using subharmonic signals from ultrasound contrast agents in patients with breast lesions.

Authors:  John R Eisenbrey; Jaydev K Dave; Daniel A Merton; Juan P Palazzo; Anne L Hall; Flemming Forsberg
Journal:  J Ultrasound Med       Date:  2011-01       Impact factor: 2.153

6.  Simultaneous grayscale and subharmonic ultrasound imaging on a modified commercial scanner.

Authors:  J R Eisenbrey; J K Dave; V G Halldorsdottir; D A Merton; P Machado; J B Liu; C Miller; J M Gonzalez; S Park; S Dianis; C L Chalek; K E Thomenius; D B Brown; V Navarro; F Forsberg
Journal:  Ultrasonics       Date:  2011-05-10       Impact factor: 2.890

Review 7.  [Ultrasound contrast agents. Pharmaceutical drug safety and bioeffects].

Authors:  M Krix; J W Jenne
Journal:  Radiologe       Date:  2007-09       Impact factor: 0.635

8.  Microbubbles traversing the blood-brain barrier for imaging and therapy.

Authors:  Stephen Meairs; Angelika Alonso; Marc Fatar; Rolf Kern; Michael Hennerici
Journal:  Med Biol Eng Comput       Date:  2009-03-13       Impact factor: 2.602

9.  Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time.

Authors:  Martin Wiesmann; Scott Berg; G Bohner; R Klingebiel; V Schöpf; B M Stoeckelhuber; I Yousry; J Linn; U Missler
Journal:  Eur Radiol       Date:  2008-07-11       Impact factor: 5.315

10.  Perfusion estimation using contrast-enhanced 3-dimensional subharmonic ultrasound imaging: an in vivo study.

Authors:  Anush Sridharan; John R Eisenbrey; Ji-Bin Liu; Priscilla Machado; Valgerdur G Halldorsdottir; Jaydev K Dave; Hongjia Zhao; Yu He; Suhyun Park; Scott Dianis; Kirk Wallace; Kai E Thomenius; Flemming Forsberg
Journal:  Invest Radiol       Date:  2013-09       Impact factor: 6.016

View more