Literature DB >> 14738932

Quantitative analysis of simvastatin and its beta-hydroxy acid in human plasma using automated liquid-liquid extraction based on 96-well plate format and liquid chromatography-tandem mass spectrometry.

Nanyan Zhang1, Amy Yang, John Douglas Rogers, Jamie J Zhao.   

Abstract

An assay based on automated liquid-liquid extraction (LLE) and liquid chromatography-tandem mass spectrometry (LC/MS/MS) has been developed and validated for the quantitative analysis of simvastatin (SV) and its beta-hydroxy acid (SVA) in human plasma. A Packard MultiProbe II workstation was used to convert human plasma samples collected following administration of simvastatin and quality control (QC) samples from individual tubes into 96-well plate format. The workstation was also used to prepare calibration standards and spike internal standards. A Tomtec Quadra 96-channel liquid handling workstation was used to perform LLE based on 96-well plates including adding solvents, separating organic from aqueous layer and reconstitution. SV and SVA were separated through a Kromasil C18 column (50 mm x 2 mm i.d., 5 microm) and detected by tandem mass spectrometry with a TurboIonspray interface. Stable isotope-labeled SV and SVA, 13CD(3)-SV and 13 CD(3)-SVA, were used as the internal standards for SV and SVA, respectively. The automated procedures reduced the overall analytical time (96 samples) to 1/3 of that of manual LLE. Most importantly, an analyst spent only a fraction of time on the 96-well LLE. A limit of quantitation of 50 pg/ml was achieved for both SV and SVA. The interconversion between SV and SVA during the 96-well LLE was found to be negligible. The assay showed very good reproducibility, with intra- and inter-assay precision (%R.S.D.) of less than 7.5%, and accuracy of 98.7-102.3% of nominal values for both analytes. By using this method, sample throughput should be enhanced at least three-fold compared to that of the manual procedure.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14738932     DOI: 10.1016/j.japna.2003.08.016

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  6 in total

1.  A Simple Protein Precipitation-based Simultaneous Quantification of Lovastatin and Its Active Metabolite Lovastatin Acid in Human Plasma by Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry using Polarity Switching.

Authors:  Ju Wujian; Peng Kuan-Wei; Yang Sihyung; Sun Huijing; Sampson Mario; Wang Michael Zhuo
Journal:  J Chromatogr Sep Tech       Date:  2015-05

2.  Quantitative determination of total methamphetamine and active metabolites in rat tissue by liquid chromatography with tandem mass spectrometric detection.

Authors:  Howard Hendrickson; Elizabeth Laurenzana; S Michael Owens
Journal:  AAPS J       Date:  2006-11-22       Impact factor: 4.009

3.  Effects of highly hygroscopic excipients on the hydrolysis of simvastatin in tablet at high relative humidity.

Authors:  W L Chen; D W Guo; Y Y Shen; S R Guo; K P Ruan
Journal:  Indian J Pharm Sci       Date:  2012-11       Impact factor: 0.975

4.  Synthesis, characterization and quantification of simvastatin metabolites and impurities.

Authors:  Manish S Bhatia; Swapnil D Jadhav; Neela M Bhatia; Prafulla B Choudhari; Kundan B Ingale
Journal:  Sci Pharm       Date:  2011-07-25

5.  Simultaneous determination of ezetimibe and simvastatin in rat plasma by stable-isotope dilution LC-ESI-MS/MS and its application to a pharmacokinetic study.

Authors:  Sireesha R Karanam; Prakash Katakam; Babu R Chandu; Nagiat T Hwisa; Shanta K Adiki
Journal:  J Pharm Anal       Date:  2013-08-16

6.  Comparison of conventional and supported liquid extraction methods for the determination of sitagliptin and simvastatin in rat plasma by LC-ESI-MS/MS.

Authors:  B Ramesh; N Manjula; S R Bijargi; V U M Sarma; P Sita Devi
Journal:  J Pharm Anal       Date:  2014-12-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.