Literature DB >> 14738681

Band leakage after laparoscopic adjustable gastric banding.

Reinhard P Mittermair1, Helmut G Weiss, Hermann Nehoda, Regina Peer, Eveline Donnemiller, Roy Moncayo, Franz Aigner.   

Abstract

BACKGROUND: Laparoscopic adjustable gastric banding is effective in inducing weight loss, as well as being minimally invasive, totally reversible, and adjustable to the patient's needs. Nevertheless, leakage of the adjustable balloon is a known complication. The aim of this study was to assess the incidence and reasons for balloon leakage of the Swedish adjustable gastric band (SAGB). PATIENTS AND METHODS: Between January 1996 and December 2002, 566 patients (475 women, 91 men) underwent a laparoscopic SAGB implantation. Two groups of patients were analyzed: patients with early postoperative leakage (Group E) and patients with late postoperative leakage (Group L). All data (age, gender, pre- and postoperative weight, time of weight gain, band filling status) were prospectively collected in a computerized data bank. For the detection of gastric band leakage, radiography and the technetium-99m colloid scintigraphy was used.
RESULTS: 25 band leakages were observed in 22 patients (4.4%). All these patients had a silent presentation of band leakage, with weight regain and an ability to eat without major restriction. Band leakages in group E were detected during the band filling period after a median follow-up of 8 months and after 30.3 months (P <0.0001) in group L. In group E, all 13 leakages possibly resulted from inappropriate handling of the device during surgery. In 2 cases in group L, a tear of the balloon had occurred where it is fixed to the band. The other 10 bands showed breaks at the edges of the inner side of the balloon. All leakages could be detected by (99m)Tc colloid scintigraphy, whereas only 58% of the leakages could be detected by radiography.
CONCLUSION: Band leakage is a rare complication and should be considered if a patient starts to regain weight. Operative failure as well as material defects may account for this complication. The balloon leakage can effectively be detected by (99m)Tc colloid-scintigraphy.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14738681     DOI: 10.1381/096089203322618768

Source DB:  PubMed          Journal:  Obes Surg        ISSN: 0960-8923            Impact factor:   4.129


  5 in total

1.  Use of standard hypodermic needles for accessing laparoscopic adjustable gastric band ports.

Authors:  Samuel Mark Bewsher; Anthony Azzi; Timothy Wright
Journal:  Obes Surg       Date:  2010-06       Impact factor: 4.129

Review 2.  All bariatric surgeries are not created equal: insights from mechanistic comparisons.

Authors:  Margaret A Stefater; Hilary E Wilson-Pérez; Adam P Chambers; Darleen A Sandoval; Randy J Seeley
Journal:  Endocr Rev       Date:  2012-05-01       Impact factor: 19.871

3.  Mechanical versus suture fixation of the port in adjustable gastric banding procedures: a prospective randomized blinded study.

Authors:  Karl A Miller; Antonia Pump
Journal:  Surg Endosc       Date:  2008-04-04       Impact factor: 4.584

Review 4.  Benchmarking best practices in weight loss surgery.

Authors:  Robert B Lim; George L Blackburn; Daniel B Jones
Journal:  Curr Probl Surg       Date:  2010-02       Impact factor: 1.909

5.  The surgical management of obesity with emphasis on the role of post operative imaging.

Authors:  F Hampson; M Sinclair; S Smith
Journal:  Biomed Imaging Interv J       Date:  2011-01-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.