Literature DB >> 14736975

Automated flow cytometry analysis of peritoneal dialysis fluid.

Joris Penders1, Tom Fiers, Annemieke M Dhondt, Geert Claeys, Joris R Delanghe.   

Abstract

BACKGROUND: Recently, the Sysmex UF-100 flow cytometer has been developed to automate urinalysis. We have evaluated this instrument to explore the possibilities of flow cytometry in the analysis of peritoneal dialysis fluid (PD) and have compared the obtained data with those of counting chamber techniques, biochemical analysis and bacterial culture.
METHODS: UF-100 data were correlated with microscopy and biochemical data in 135 PD samples. Microbiological analysis was performed in 63 suspected cases of peritonitis.
RESULTS: Good agreement (P < 0.001) was obtained between UF-100 and microscopy data for leukocytes (r = 0.825). UF-100 bacterial count correlated (P < 0.001) with UF-100 leukocyte count (r = 0.549). UF-100 bacterial counts were unreliable in samples where interference by blood platelets was observed. Another major problem was the UF-100 'bacterial' background signal in sterile PD samples. Yeast cells were detected by the flow cytometer in spiked samples.
CONCLUSIONS: Flow cytometry of PD with the UF-100 offers a rapid and reliable leukocyte count. Sensitivity of the 'bacterial' channel count in predicting positive culture exceeds the sensitivity of conventional Gram stain. Furthermore, additional semi-quantitative information is provided regarding the presence of yeasts.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14736975     DOI: 10.1093/ndt/gfg552

Source DB:  PubMed          Journal:  Nephrol Dial Transplant        ISSN: 0931-0509            Impact factor:   5.992


  3 in total

1.  Asymptomatic peritoneal leukocytosis after exteriorization of buried peritoneal dialysis catheters: a case series.

Authors:  Randah Dahlan; Joanne M Bargman; Mohan Biyani; Susan Lavoie; Brendan B McCormick
Journal:  Perit Dial Int       Date:  2015 Jan-Feb       Impact factor: 1.756

2.  Evaluation of flow cytometry for the detection of bacteria in biological fluids.

Authors:  Elisa Rubio; Yuliya Zboromyrska; Jordi Bosch; Mariana J Fernandez-Pittol; Berta I Fidalgo; Assumpta Fasanella; Anna Mons; Angely Román; Climent Casals-Pascual; Jordi Vila
Journal:  PLoS One       Date:  2019-08-07       Impact factor: 3.240

3.  Evaluation of Flow Cytometry for Cell Count and Detection of Bacteria in Biological Fluids.

Authors:  N Dossou; I Gaubert; C Moriceau; E Cornet; S le Hello; D Malandain
Journal:  Microbiol Spectr       Date:  2022-02-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.