The purpose of this study was to determine if the temperatures obtained using a veterinary infrared (IR) thermometer agreed with a digital rectal thermometer in a group of research cats, half of which had transient fevers. The thermometers were weakly correlated (r=0.62). The mean difference was 0.13 degrees F (0.07 degrees C), and the limits of agreement were 2.6 degrees F (1.43 degrees C) and -2.5 degrees F (-1.36 degrees C), which were unacceptable for clinical purposes. The results of this study indicate that, while the IR thermometer was easy to use, it cannot be used interchangeably with the rectal thermometer.Entities:
Mesh:
Year: 2004 PMID: 14736904 DOI: 10.5326/0400042
Source DB: PubMed Journal: J Am Anim Hosp Assoc ISSN: 0587-2871 Impact factor: 1.023