Literature DB >> 14729723

Hemodynamic response and oxygen transport in pigs resuscitated with maleimide-polyethylene glycol-modified hemoglobin (MP4).

Dan Drobin1, B Thomas Kjellstrom, Elisabeth Malm, Ashok Malavalli, Jeff Lohman, Kim D Vandegriff, Mark A Young, Robert M Winslow.   

Abstract

Cell-free Hb increases systemic and pulmonary pressure and resistance and reduces cardiac output and heart rate in animals and humans, effects that have limited their clinical development as "blood substitutes." The primary aim of this study was to evaluate the hemodynamic response to infusion of several formulations of a new polyethylene glycol (PEG)-modified human Hb [maleimide PEG Hb (MalPEGHb)] in swine, an animal known to be sensitive to Hb-induced vasoconstriction. Anesthetized animals underwent controlled hemorrhage (50% of blood volume), followed by resuscitation (70% of shed volume) with 10% pentastarch (PS), 4% MalPEG-Hb in lactated Ringer (MP4), 4% MalPEG-Hb in pentastarch (HS4), 2% MalPEG-Hb in pentastarch (HS2), or 4% stroma-free Hb in lactated Ringer solution (SFH). Compared with baseline, restoration of blood volume after resuscitation was similar and not significantly different for the PS (103%), HS2 (99%), HS4 (106%), and MP4 (87%) animals but significantly less for the SFH animals (66%) (P < 0.05). All solutions that contained MalPEG-Hb restored mean arterial and pulmonary pressure and cardiac output. Systemic vascular resistance was unchanged, and pulmonary arterial pressure and resistance were increased slightly. Both systemic and pulmonary vascular resistance increased significantly in animals that received SFH, despite less adequate blood volume restoration. Oxygen consumption was maintained in all animals that received MalPEG-Hb, but not PS. Base excess improved only with MalPEG-Hb and PS, but not SFH. Red blood cell O2 extraction was significantly increased in animals that received Hb, regardless of formulation. These data demonstrate resuscitation with MalPEG-human Hb without increasing systemic vascular resistance and support our previous observations in animals suggesting that the efficacy of low concentrations of PEG-Hb in the plasma results from reduced vasoconstriction.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14729723     DOI: 10.1152/japplphysiol.00530.2003

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  4 in total

Review 1.  Haemoglobin-based oxygen carriers: research and reality towards an alternative to blood transfusions.

Authors:  Andrea Mozzarelli; Luca Ronda; Serena Faggiano; Stefano Bettati; Stefano Bruno
Journal:  Blood Transfus       Date:  2010-06       Impact factor: 3.443

Review 2.  [Artificial oxygen carriers as an alternative to red blood cell transfusion].

Authors:  O Habler; A Pape; J Meier; B Zwissler
Journal:  Anaesthesist       Date:  2005-08       Impact factor: 1.041

3.  Solution structure of poly(ethylene) glycol-conjugated hemoglobin revealed by small-angle X-ray scattering: implications for a new oxygen therapeutic.

Authors:  Dmitri I Svergun; Fredrik Ekström; Kim D Vandegriff; Ashok Malavalli; Dale A Baker; Calle Nilsson; Robert M Winslow
Journal:  Biophys J       Date:  2007-09-07       Impact factor: 4.033

4.  Effects of maleimide-polyethylene glycol-modified human hemoglobin (MP4) on tissue necrosis in SKH1-hr hairless mice.

Authors:  Ole Goertz; M H Kirschner; H Lilienfein; P Babilas; H U Steinau; C Andree; A Daigeler; A Stachon; H Homann; S Langer
Journal:  Eur J Med Res       Date:  2009-03-17       Impact factor: 2.175

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.