3D imaging with a single-sided sensor: an open tomograph.

J Perlo1, F Casanova, B Blümich.   

Abstract

An open tomograph to image volume regions near the surface of large objects is described. The central achievement in getting such a tomograph to work is the design of a fast two-dimensional pure phase encoding imaging method to produce a cross-sectional image in the presence of highly inhomogeneous fields. The method takes advantage of the multi-echo acquisition in a Carr-Purcell-Meiboom-Gill (CPMG)-like sequence to significantly reduce the experimental time to obtain a 2D image or to spatially resolve relaxation times across the sensitive volume in a single imaging experiment. Depending on T(2) the imaging time can be reduced by a factor of up to two orders of magnitude compared to the one needed by the single-echo imaging technique. The complete echo train decay has been also used to produce T(2) contrast in the images and to spatially resolve the T(2) distribution of an inhomogeneous object, showing that variations of structural properties like the cross-link density of rubber samples can be distinguished by this method. The sequence has been implemented on a single-sided sensor equipped with an optimized magnet geometry and a suitable gradient coil system that provides two perpendicular pulsed gradient fields. The static magnetic field defines flat planes of constant frequency parallel to the surface of the scanner that can be selected by retuning the probe frequency to achieve slice selection into the object. Combining the slice selection obtained under the presence of the static gradient of the open magnet with the two perpendicular pulsed gradient fields, 3D spatial resolution is obtained.

Mesh:

Year:  2004        PMID: 14729034     DOI: 10.1016/j.jmr.2003.10.018

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  10 in total

1.  "Shim pulses" for NMR spectroscopy and imaging.

Authors:  Daniel Topgaard; Rachel W Martin; Dimitris Sakellariou; Carlos A Meriles; Alexander Pines
Journal:  Proc Natl Acad Sci U S A       Date:  2004-12-09       Impact factor: 11.205

2.  A novel technique for imaging with inhomogeneous fields.

Authors:  Charles L Epstein; Jeremy Magland
Journal:  J Magn Reson       Date:  2006-09-08       Impact factor: 2.229

3.  The MR Cap: A single-sided MRI system designed for potential point-of-care limited field-of-view brain imaging.

Authors:  Patrick C McDaniel; Clarissa Zimmerman Cooley; Jason P Stockmann; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2019-06-23       Impact factor: 4.668

4.  Volume-selective magnetic resonance imaging using an adjustable, single-sided, portable sensor.

Authors:  Jeffrey L Paulsen; Louis S Bouchard; Dominic Graziani; Bernhard Blümich; Alexander Pines
Journal:  Proc Natl Acad Sci U S A       Date:  2008-12-17       Impact factor: 11.205

5.  Ultimate MRI.

Authors:  Lawrence L Wald
Journal:  J Magn Reson       Date:  2019-07-09       Impact factor: 2.229

6.  Transmit Array Spatial Encoding (TRASE) using broadband WURST pulses for RF spatial encoding in inhomogeneous B0 fields.

Authors:  Jason P Stockmann; Clarissa Z Cooley; Bastien Guerin; Matthew S Rosen; Lawrence L Wald
Journal:  J Magn Reson       Date:  2016-04-08       Impact factor: 2.229

7.  Two-dimensional imaging in a lightweight portable MRI scanner without gradient coils.

Authors:  Clarissa Zimmerman Cooley; Jason P Stockmann; Brandon D Armstrong; Mathieu Sarracanie; Michael H Lev; Matthew S Rosen; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-03-25       Impact factor: 4.668

8.  Design and experimental validation of a unilateral magnet for MRI-guided small animal radiation experiments.

Authors:  Jace Grandinetti; Yuncheng Zhong; Chenyang Shen; Xun Jia
Journal:  J Magn Reson       Date:  2021-09-16       Impact factor: 2.229

9.  Development of a Single-Sided Nuclear Magnetic Resonance Scanner for the In Vivo Quantification of Live Cattle Marbling.

Authors:  Yoshito Nakashima
Journal:  Appl Magn Reson       Date:  2015-03-18       Impact factor: 0.831

10.  The Novel Design of a Single-Sided MRI Probe for Assessing Burn Depth.

Authors:  Zhonghua He; Wei He; Jiamin Wu; Zheng Xu
Journal:  Sensors (Basel)       Date:  2017-03-06       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.