Literature DB >> 14727757

Measurement of fluorophore concentrations and fluorescence quantum yield in tissue-simulating phantoms using three diffusion models of steady-state spatially resolved fluorescence.

Kevin R Diamond1, Thomas J Farrell, Michael S Patterson.   

Abstract

Steady-state diffusion theory models of fluorescence in tissue have been investigated for recovering fluorophore concentrations and fluorescence quantum yield. Spatially resolved fluorescence, excitation and emission reflectance Carlo simulations, and measured using a multi-fibre probe on tissue-simulating phantoms containing either aluminium phthalocyanine tetrasulfonate (AlPcS4), Photofrin meso-tetra-(4-sulfonatophenyl)-porphine dihydrochloride The accuracy of the fluorophore concentration and fluorescence quantum yield recovered by three different models of spatially resolved fluorescence were compared. The models were based on: (a) weighted difference of the excitation and emission reflectance, (b) fluorescence due to a point excitation source or (c) fluorescence due to a pencil beam excitation source. When literature values for the fluorescence quantum yield were used for each of the fluorophores, the fluorophore absorption coefficient (and hence concentration) at the excitation wavelength (mu(a,x,f)) was recovered with a root-mean-square accuracy of 11.4% using the point source model of fluorescence and 8.0% using the more complicated pencil beam excitation model. The accuracy was calculated over a broad range of optical properties and fluorophore concentrations. The weighted difference of reflectance model performed poorly, with a root-mean-square error in concentration of about 50%. Monte Carlo simulations suggest that there are some situations where the weighted difference of reflectance is as accurate as the other two models, although this was not confirmed experimentally. Estimates of the fluorescence quantum yield in multiple scattering media were also made by determining mu(a,x,f) independently from the fitted absorption spectrum and applying the various diffusion theory models. The fluorescence quantum yields for AlPcS4 and TPPS4 were calculated to be 0.59 +/- 0.03 and 0.121 +/- 0.001 respectively using the point source model, and 0.63 +/- 0.03 and 0.129 +/- 0.002 using the pencil beam excitation model. These results are consistent with published values.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14727757     DOI: 10.1088/0031-9155/48/24/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Experimental recovery of intrinsic fluorescence and fluorophore concentration in the presence of hemoglobin: spectral effect of scattering and absorption on fluorescence.

Authors:  Vinh Nguyen Du Le; Michael S Patterson; Thomas J Farrell; Joseph E Hayward; Qiyin Fang
Journal:  J Biomed Opt       Date:  2015       Impact factor: 3.170

Review 2.  A review of attenuation correction techniques for tissue fluorescence.

Authors:  Robert S Bradley; Maureen S Thorniley
Journal:  J R Soc Interface       Date:  2006-02-22       Impact factor: 4.118

3.  Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction.

Authors:  Adam J Dixon; John A Hossack
Journal:  J Biomed Opt       Date:  2013-05       Impact factor: 3.170

4.  Experimental validation of an inverse fluorescence Monte Carlo model to extract concentrations of metabolically relevant fluorophores from turbid phantoms and a murine tumor model.

Authors:  Chengbo Liu; Narasimhan Rajaram; Karthik Vishwanath; Tony Jiang; Gregory M Palmer; Nirmala Ramanujam
Journal:  J Biomed Opt       Date:  2012-07       Impact factor: 3.170

5.  Monte-Carlo-based model for the extraction of intrinsic fluorescence from turbid media.

Authors:  Gregory M Palmer; Nirmala Ramanujam
Journal:  J Biomed Opt       Date:  2008 Mar-Apr       Impact factor: 3.170

6.  Recovery of intrinsic fluorescence from single-point interstitial measurements for quantification of doxorubicin concentration.

Authors:  Timothy M Baran; Thomas H Foster
Journal:  Lasers Surg Med       Date:  2013-08-23       Impact factor: 4.025

7.  Intrinsic Raman spectroscopy for quantitative biological spectroscopy part I: theory and simulations.

Authors:  Wei-Chuan Shih; Kate L Bechtel; Michael S Feld
Journal:  Opt Express       Date:  2008-08-18       Impact factor: 3.894

8.  QSIM: quantitative structured illumination microscopy image processing in ImageJ.

Authors:  Liang Gao
Journal:  Biomed Eng Online       Date:  2015-01-14       Impact factor: 2.819

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.